Version: 2024.08
Loading Scheme...
CPC | COOPERATIVE PATENT CLASSIFICATION | |||
| F22G | WARNING
|
F22G 1/00 | Steam superheating characterised by heating method (exothermal chemical reactions not involving a supply of free oxygen gas, apparatus or devices for using the heat therefrom F24V 30/00) [2018-05] |
F22G 1/005 | . | {the heat being supplied by steam} [2013-01] |
F22G 1/02 | . | with heat supply by hot flue gases from the furnace of the steam boiler [2013-01] |
F22G 1/04 | . . | by diverting flow or hot flue gases to separate superheaters operating in reheating cycle, e.g. for reheating steam between a high-pressure turbine stage and an intermediate turbine stage [2013-01] |
F22G 1/06 | . | with heat supply predominantly by radiation [2013-01] |
F22G 1/08 | . . | from heated brickwork or the like [2013-01] |
F22G 1/10 | . | with provision for superheating by throttling [2013-01] |
F22G 1/12 | . | by mixing steam with furnace gases or other combustion products [2013-01] |
F22G 1/14 | . | using heat generated by chemical reactions [2013-01] |
F22G 1/16 | . | by using a separate heat source independent from heat supply of the steam boiler, e.g. by electricity, by auxiliary combustion of fuel oil [2013-01] |
F22G 1/165 | . . | {by electricity (steam generation in boilers heated electrically, in general, F22B 1/28)} [2013-01] |
F22G 3/00 | Steam superheaters characterised by constructional features; Details of component parts thereof (general aspects of enclosed heat-exchangers F28D) [2013-01] |
F22G 3/001 | . | {Steam tube arrangements not dependent of location (characterised by location F22G 7/00)} [2013-01] |
F22G 3/002 | . . | {with helical steam tubes} [2013-01] |
F22G 3/003 | . | {Superheater drain arrangements} [2013-01] |
F22G 3/004 | . | {Steam tubes with steam flowing in opposite directions in one pipe, e.g. Field tubes (F22G 3/005 takes precedence)} [2013-01] |
F22G 3/005 | . | {Annular steam tubes, i.e. the steam being heated between concentric tubes with the heating fluid flowing in inner and around outer tube} [2013-01] |
F22G 3/006 | . | {Steam superheaters with heating tubes (F22G 3/005 takes precedence)} [2013-01] |
F22G 3/007 | . | {Headers; Collectors, e.g. for mixing} [2013-01] |
F22G 3/008 | . | {Protection of superheater elements, e.g. cooling superheater tubes during starting-up periods, water tube screens} [2013-01] |
F22G 3/009 | . | {Connecting or sealing of superheater or reheater tubes with collectors or distributors} [2013-01] |
F22G 5/00 |
F22G 5/02 | . | Applications of combustion-control devices, e.g. tangential-firing burners, tilting burners [2017-05] |
F22G 5/04 | . | by regulating flue gas flow, e.g. by proportioning or diverting [2013-01] |
F22G 5/06 | . | by recirculating flue gases [2013-01] |
F22G 5/08 | . . | preventing furnace gas backflow through recirculating fan [2013-01] |
F22G 5/10 | . | by displacing superheater sections [2013-01] |
F22G 5/12 | . | by attemperating the superheated steam, e.g. by injected water sprays (spray mixers B01F 25/70) [2022-01] |
F22G 5/123 | . . | {Water injection apparatus} [2013-01] |
F22G 5/126 | . . . | {in combination with steam-pressure reducing valves} [2013-01] |
F22G 5/14 | . . | by live steam [2013-01] |
F22G 5/16 | . | by indirectly cooling or heating the superheated steam in auxiliary enclosed heat-exchanger [2013-01] |
F22G 5/18 | . | by by-passing steam around superheater sections [2013-01] |
F22G 5/20 | . | by combined controlling procedures [2013-01] |
F22G 7/00 | Steam superheaters characterised by location, arrangement, or disposition [2013-01] |
F22G 7/005 | . | {for locomotive boilers (F22G 7/065, F22G 7/105 take precedence)} [2013-01] |
F22G 7/02 | . | in fire tubes [2013-01] |
F22G 7/04 | . | in jackets around fire tubes [2013-01] |
F22G 7/06 | . | in furnace tubes [2013-01] |
F22G 7/065 | . . | {for locomotive boilers} [2013-01] |
F22G 7/08 | . | in fire-boxes [2013-01] |
F22G 7/10 | . | in smoke-boxes [2013-01] |
F22G 7/105 | . . | {for locomotive boilers} [2013-01] |
F22G 7/12 | . | in flues [2013-01] |
F22G 7/14 | . | in water-tube boilers, e.g. between banks of water tubes [2013-01] |
F22G 7/145 | . . | {of inclined type, i.e. the water-tube sets being inclined with respect to the horizontal plane} [2013-01] |