Version: 2024.08
Loading Scheme...
CPC | COOPERATIVE PATENT CLASSIFICATION | |||
| F03D | WIND MOTORS [2018-05] NOTES
|
| F03D 1/00 | Wind motors with rotation axis substantially parallel to the air flow entering the rotor (controlling thereof F03D 7/02) [2023-08] WARNING
|
F03D 1/02 | . | having a plurality of rotors [2019-05] |
F03D 1/025 | . . | {coaxially arranged} [2019-05] |
| F03D 1/04 | . | having stationary wind-guiding means, e.g. with shrouds or channels (F03D 9/35 takes precedence) [2023-08] WARNING
|
| F03D 1/041 | . . | {Convergent inlets, i.e. the inlet section is greater than the rotor section (F03D 1/044 takes precedence)} [2023-08] WARNING
|
| F03D 1/042 | . . | {Divergent outlets, e.g. diffusers or ejectors (F03D 1/044 takes precedence)} [2023-08] WARNING
|
| F03D 1/044 | . . | {Convergent divergent structures, e.g. venturis} [2023-08] WARNING
|
| F03D 1/046 | . . | {comprising additional flow modifying means, e.g. vanes or turbulators} [2023-08] WARNING
|
| F03D 1/048 | . . . | {for changing the flow direction, e.g. a horizontal inlet and a vertical outlet} [2023-08] |
| F03D 1/051 | . . | {Multiple shrouds, e.g. in series or in parallel} [2023-08] WARNING
|
| F03D 1/053 | . . | {comprising controllable elements, e.g. inlet valves or shutters} [2023-08] WARNING
|
| F03D 1/06 | . | Rotors [2023-08] WARNING
|
F03D 1/0601 | . . | {using the Magnus effect} [2023-08] |
| F03D 1/0602 | . . | {having rotating wind-guiding means, e.g. associated with the hub} [2023-08] WARNING
|
| F03D 1/0606 | . . . | {Shrouds} [2023-08] WARNING
|
| F03D 1/0608 | . . | {characterised by their aerodynamic shape} [2023-08] WARNING
|
| F03D 1/0625 (Frozen) | . . . | {of the whole rotor, i.e. form features of the rotor unit} [2023-08] WARNING
|
| F03D 1/0633 | . . . | {of the blades} [2023-08] WARNING
|
| F03D 1/0641 | . . . . | {of the section profile of the blades, i.e. aerofoil profile} [2023-08] WARNING
|
| F03D 1/0642 | . . . . | {of the blade tip region} [2023-08] WARNING
|
| F03D 1/0643 | . . . . | {of the leading edge region} [2023-08] WARNING
|
| F03D 1/0645 | . . . . | {of the trailing edge region} [2023-08] WARNING
|
| F03D 1/0647 | . . . . | {of the root or transition region} [2023-08] WARNING
|
| F03D 1/0648 | . . . . | {of changeable form, e.g. comprising inflatable elements} [2023-08] WARNING
|
| F03D 1/0649 | . . . . | {of the blade surfaces, e.g. roughened} [2023-08] WARNING
|
| F03D 1/06495 | . . . . | {Aerodynamic elements attached to or formed with the blade, e.g. flaps, vortex generators or noise reducers} [2023-08] WARNING
|
| F03D 1/065 | . . | {characterised by their construction elements (F03D 13/10 takes precedence)} [2023-08] WARNING
|
| F03D 1/0658 | . . . | {Arrangements for fixing wind-engaging parts to a hub} [2023-08] WARNING
|
| F03D 1/066 | . . . . | {Connection means therefor, e.g. bushings or adapters} [2023-08] WARNING
|
| F03D 1/0662 | . . . . | {using kinematic linkage, e.g. tilt (bearing arrangements, pitch bearings F03D 80/70)} [2023-08] WARNING
|
| F03D 1/0664 | . . . . . | {Pitch arrangements (controlling blade pitch F03D 7/0224)} [2023-08] WARNING
|
| F03D 1/0667 | . . . . . . | {characterized by the actuator arrangements} [2023-08] WARNING
|
| F03D 1/0669 | . . . . . . . | {Hydraulic actuators} [2023-08] WARNING
|
| F03D 1/0671 | . . . . . . . | {Electric actuators, e.g. motors} [2023-08] WARNING
|
| F03D 1/0675 | . . . | {of the blades} [2023-08] WARNING
|
| F03D 1/0677 | . . . . | {Longitudinally segmented blades; Connectors therefor} [2023-08] WARNING
|
| F03D 1/0679 | . . . . | {Load carrying structures, e.g. beams} [2023-08] WARNING
|
F03D 1/0681 | . . . . . | {Spar caps} [2023-08] |
F03D 1/0682 | . . . . . . | {incorporated into the shell structure} [2023-08] |
F03D 1/0684 | . . . . . | {Shear webs} [2023-08] |
| F03D 1/0685 | . . . . | {Actuation arrangements for elements attached to or incorporated with the blade (controlling flaps or slats F03D 7/0232)} [2023-08] WARNING
|
| F03D 1/0687 | . . . . | {of the blade tip region} [2023-08] WARNING
|
| F03D 1/0688 | . . . . | {of the leading edge region, e.g. reinforcements} [2023-08] WARNING
|
| F03D 1/069 | . . . . | {of the trailing edge region} [2023-08] WARNING
|
F03D 1/0691 | . . . | {of the hub} [2013-01] |
| F03D 1/101 | . | {Nacelles (arrangement of components within nacelles F03D 80/80)} [2023-08] WARNING
|
F03D 1/125 | . . | {Access thereto, e.g. doors or platforms} [2023-08] |
F03D 1/141 | . . | {Supporting structures, i.e. load carrying structures} [2023-08] |
F03D 1/165 | . . | {Fairings, i.e. elements defining or supporting the outer surface} [2023-08] |
| F03D 1/181 | . . | {characterised by the connection to the tower, e.g. yaw systems (controlling the orientation in relation to wind direction F03D 7/0204)} [2023-08] WARNING
|
F03D 1/188 | . . | {made of several pieces and assembled on-site (assembly of wind motors F03D 13/10)} [2023-08] |
F03D 3/00 | Wind motors with rotation axis substantially perpendicular to the air flow entering the rotor (controlling thereof F03D 7/06) [2018-05] |
F03D 3/002 | . | {the axis being horizontal} [2023-08] |
| F03D 3/005 | . | {the axis being vertical} [2023-08] WARNING
|
F03D 3/007 | . . | {using the Magnus effect} [2013-01] |
| F03D 3/009 | . . | {of the drag type, e.g. Savonius} [2023-08] WARNING
|
| F03D 3/011 | . . | {of the lift type, e.g. Darrieus or Musgrove} [2023-08] WARNING
|
F03D 3/02 | . | having a plurality of rotors [2019-05] |
F03D 3/04 | . | having stationary wind-guiding means, e.g. with shrouds or channels (F03D 9/35 takes precedence) [2019-05] |
F03D 3/0409 | . . | {surrounding the rotor (F03D 3/0427 takes precedence)} [2023-08] |
F03D 3/0418 | . . . | {comprising controllable elements} [2023-08] |
F03D 3/0427 | . . | {with converging inlets, i.e. the guiding means intercepting an area greater than the effective rotor area (F03D 3/0463, F03D 3/049 take precedence)} [2023-08] |
F03D 3/0436 | . . | {for shielding one side of the rotor} [2023-08] |
F03D 3/0445 | . . . | {the shield being fixed with respect to the wind motor} [2023-08] |
F03D 3/0454 | . . . . | {and only with concentrating action, i.e. only increasing the airflow speed into the rotor, e.g. divergent outlets (F03D 3/0463 takes precedence)} [2023-08] |
F03D 3/0463 | . . . . | {with converging inlets, i.e. the shield intercepting an area greater than the effective rotor area} [2023-08] |
F03D 3/0472 | . . . | {the shield orientation being adaptable to the wind motor} [2023-08] |
F03D 3/0481 | . . . . | {and only with concentrating action, i.e. only increasing the airflow speed into the rotor, e.g. divergent outlets (F03D 3/049 takes precedence)} [2023-08] |
F03D 3/049 | . . . . | {with converging inlets, i.e. the shield intercepting an area greater than the effective rotor area} [2023-08] |
F03D 3/06 | . | Rotors [2017-08] |
F03D 3/061 | . . | {characterised by their aerodynamic shape, e.g. aerofoil profiles} [2023-08] |
| F03D 3/062 | . . | {characterised by their construction elements} [2023-08] WARNING
|
| F03D 3/063 | . . . | {Telescoping or folding wind engaging parts} [2023-08] WARNING
|
F03D 3/064 | . . . | {Fixing wind engaging parts to rest of rotor} [2013-01] |
| F03D 3/066 | . . . | {the wind engaging parts being movable relative to the rotor} [2023-08] WARNING
|
| F03D 3/067 | . . . . | {Cyclic movements} [2023-08] WARNING
|
| F03D 3/068 | . . . . . | {mechanically controlled by the rotor structure} [2023-08] WARNING
|
| F03D 5/00 | WARNING
|
F03D 5/005 | . | {Wind motors having a single vane which axis generate a conus or like surface} [2013-01] |
| F03D 5/015 | . | {of the tethered aircraft type, e.g. kites, with traction and retraction of the tether (controlling thereof F03D 7/051)} [2023-08] WARNING
|
F03D 5/02 | . | the wind-engaging parts being attached to endless chains or the like [2013-01] |
F03D 5/04 | . | the wind-engaging parts being attached to carriages running on tracks or the like [2013-01] |
F03D 5/06 | . | the wind-engaging parts swinging to-and-fro and not rotating [2013-01] |
| F03D 7/00 | Controlling wind motors (supplying or distributing electrical power H02J, e.g. arrangements for adjusting, eliminating or compensating reactive power in networks H02J 3/18; controlling electric generators H02P, e.g. arrangements for controlling electric generators for the purpose of obtaining a desired output H02P 9/00) [2023-08] WARNING
|
| F03D 7/02 | . | the wind motors having rotation axis substantially parallel to the air flow entering the rotor [2023-08] WARNING
|
| F03D 7/0202 | . . | {controlling floating wind motors} [2023-08] WARNING
|
| F03D 7/0204 | . . | {for orientation in relation to wind direction} [2023-08] WARNING
|
F03D 7/0208 | . . . | {Orientating out of wind} [2013-01] |
F03D 7/0212 | . . . . | {the rotating axis remaining horizontal} [2013-01] |
F03D 7/0216 | . . . . | {the rotating axis changing to vertical position} [2013-01] |
F03D 7/022 | . . | {Adjusting aerodynamic properties of the blades} [2013-01] |
| F03D 7/0224 | . . . | {Adjusting blade pitch} [2023-08] WARNING
|
F03D 7/0228 | . . . . | {of the blade tips only} [2013-01] |
| F03D 7/0232 | . . . | {with flaps or slats (with aerodynamic drag devices on the blades for braking F03D 7/0252)} [2023-08] WARNING
|
| F03D 7/0236 | . . . | {by changing the active surface of the wind engaging parts, e.g. reefing or furling} [2023-08] WARNING
|
| F03D 7/0237 | . . . . | {by means of telescoping blades} [2023-08] WARNING
|
| F03D 7/0239 | . . . . | {by means of teetering or coning blades} [2023-08] WARNING
|
F03D 7/024 | . . . | {of individual blades} [2013-01] |
F03D 7/0244 | . . | {for braking} [2013-01] |
F03D 7/0248 | . . . | {by mechanical means acting on the power train} [2013-01] |
F03D 7/0252 | . . . | {with aerodynamic drag devices on the blades} [2013-01] |
F03D 7/0256 | . . | {Stall control (adjusting the blades in stall position F03D 7/0224)} [2013-01] |
F03D 7/026 | . . | {for starting-up} [2013-01] |
F03D 7/0264 | . . | {for stopping; controlling in emergency situations (orientating out of wind F03D 7/0208)} [2023-08] |
F03D 7/0268 | . . . | {Parking or storm protection} [2013-01] |
F03D 7/0272 | . . | {by measures acting on the electrical generator} [2023-08] |
F03D 7/0276 | . . | {controlling rotor speed, e.g. variable speed} [2023-08] |
| F03D 7/028 | . . | {controlling wind motor output power} [2023-08] WARNING
|
F03D 7/0284 | . . . | {in relation to the state of the electric grid} [2023-08] |
| F03D 7/0288 | . . . | {in relation to clearance between the blade and the tower, i.e. preventing tower strike} [2023-08] WARNING
|
F03D 7/0292 | . . . | {to reduce fatigue} [2023-08] |
| F03D 7/0296 | . . | {to prevent, counteract or reduce noise emissions} [2023-08] WARNING
|
| F03D 7/0298 | . . | {to prevent, counteract or reduce vibrations} [2023-08] WARNING
|
F03D 7/0302 | . . . | {of the tower} [2023-08] |
F03D 7/04 | . . | Automatic control; Regulation [2013-01] |
F03D 7/041 | . . . | {by means of a mechanical governor} [2013-01] |
F03D 7/042 | . . . | {by means of an electrical or electronic controller} [2013-01] |
F03D 7/043 | . . . . | {characterised by the type of control logic} [2013-01] |
F03D 7/044 | . . . . . | {with PID control} [2013-01] |
F03D 7/045 | . . . . . | {with model-based controls} [2013-01] |
F03D 7/046 | . . . . . | {with learning or adaptive control, e.g. self-tuning, fuzzy logic or neural network} [2013-01] |
F03D 7/047 | . . . . | {characterised by the controller architecture, e.g. multiple processors or data communications} [2013-01] |
| F03D 7/048 | . . . . | {controlling wind farms} [2023-08] WARNING
|
| F03D 7/049 | . . . . . | {in relation to the wake effect} [2023-08] WARNING
|
| F03D 7/051 | . | {the wind motors being supported in air by airborne structures; of the tethered aircraft type} [2023-08] WARNING
|
| F03D 7/06 | . | the wind motors having rotation axis substantially perpendicular to the air flow entering the rotor [2023-08] WARNING
|
| F03D 7/065 | . . | {controlling rotor speed} [2023-08] WARNING
|
F03D 9/00 | Adaptations of wind motors for special use; Combinations of wind motors with apparatus driven thereby; Wind motors specially adapted for installation in particular locations (hybrid wind-photovoltaic energy systems for the generation of electric power H02S 10/12) [2019-05] |
F03D 9/007 | . | {the wind motor being combined with means for converting solar radiation into useful energy} [2019-05] |
F03D 9/008 | . | {the wind motor being combined with water energy converters, e.g. a water turbine} [2019-05] |
F03D 9/10 | . | Combinations of wind motors with apparatus storing energy [2019-05] |
F03D 9/11 | . . | storing electrical energy [2019-05] |
F03D 9/12 | . . | storing kinetic energy, e.g. using flywheels [2019-05] |
F03D 9/13 | . . | storing gravitational potential energy [2019-05] |
F03D 9/14 | . . . | using liquids [2019-05] |
F03D 9/16 | . . . | using weights [2019-05] |
F03D 9/17 | . . | storing energy in pressurised fluids [2019-05] |
F03D 9/18 | . . | storing heat [2019-05] |
F03D 9/19 | . . | storing chemical energy, e.g. using electrolysis [2019-05] |
F03D 9/20 | . |
F03D 9/22 | . . | the apparatus producing heat [2019-05] |
| F03D 9/25 | . . | WARNING
|
F03D 9/28 | . . | the apparatus being a pump or a compressor [2019-05] |
| F03D 9/30 | . | Wind motors specially adapted for installation in particular locations (means for mounting or supporting wind motors F03D 13/20) [2023-08] WARNING
|
| F03D 9/32 | . . | on moving objects, e.g. vehicles [2023-08] WARNING
|
| F03D 9/322 | . . . | {the wind motors being supported in air by airborne structures, e.g. by kites (controlling thereof F03D 7/051)} [2023-08] WARNING
|
| F03D 9/324 | . . . . | {following a flying pattern} [2023-08] WARNING
|
F03D 9/34 | . . | on stationary objects or on stationary man-made structures [2019-05] |
| F03D 9/35 | . . . | within towers, e.g. using chimney effects [2023-08] WARNING
|
| F03D 9/37 | . . . . | with means for enhancing the air flow within the tower, e.g. by heating [2023-08] WARNING
|
| F03D 9/39 | . . . . . | by circulation or vortex formation [2023-08] WARNING
|
| F03D 9/41 | . . . . . | by using the wind outside the tower, e.g. using ejectors [2023-08] WARNING
|
F03D 9/43 | . . . | using infrastructure primarily used for other purposes, e.g. masts for overhead railway power lines [2019-05] |
F03D 9/45 | . . . . | Building formations [2019-05] |
F03D 9/46 | . . . . | Tunnels or streets [2019-05] |
F03D 9/48 | . . | using landscape topography, e.g. valleys [2019-05] |
F03D 13/00 | Assembly, mounting or commissioning of wind motors; Arrangements specially adapted for transporting wind motor components [2019-05] |
| F03D 13/10 | . | Assembly of wind motors; Arrangements for erecting wind motors [2023-08] WARNING
|
| F03D 13/104 | . . | {Rotor installation, e.g. installation of blades} [2023-08] WARNING
|
| F03D 13/108 | . . . | {Alignment, e.g. of blades to rotor hub} [2023-08] WARNING
|
| F03D 13/112 | . . | {of towers; of masts} [2023-08] WARNING
|
| F03D 13/116 | . . | {of nacelles} [2023-08] WARNING
|
| F03D 13/122 | . . | {of auxiliary arrangements inside tower or nacelle, e.g. generators or transmission} [2023-08] WARNING
|
| F03D 13/126 | . . | {Offshore} [2023-08] WARNING
|
| F03D 13/135 | . . | {Pre-assembling, i.e. partially or completely assembling the wind motor before transport to the installation site} [2023-08] WARNING
|
| F03D 13/139 | . . | {Assembling or erecting wind motors by using lifting means} [2023-08] WARNING
|
| F03D 13/20 | . | Arrangements for mounting or supporting wind motors; Masts or towers for wind motors [2023-08] WARNING
|
| F03D 13/2005 | . . | {Masts or poles} [2023-08] WARNING
|
| F03D 13/201 | . . | {Towers} [2023-08] WARNING
|
F03D 13/202 | . . . | {Access thereto} [2023-08] |
| F03D 13/203 | . . . | {Lattice truss} [2023-08] WARNING
|
| F03D 13/204 | . . . | {Circumferentially segmented} [2023-08] WARNING
|
| F03D 13/205 | . . . | {Connection means, e.g. joints between segments} [2023-08] WARNING
|
| F03D 13/22 (Frozen) | . . | {Foundations specially adapted for wind motors} [2023-08] WARNING
|
| F03D 13/25 | . . | specially adapted for offshore installation [2023-08] WARNING
|
| F03D 13/256 | . . . | {on a floating support, i.e. floating wind motors} [2023-08] WARNING
|
| F03D 13/30 | . | Commissioning, e.g. inspection, testing or final adjustment before releasing for production [2023-08] WARNING
|
F03D 13/35 | . . | Balancing static or dynamic imbalances [2017-02] |
| F03D 13/40 | . | Arrangements or methods specially adapted for transporting wind motor components [2023-08] WARNING
|
| F03D 13/401 | . . | {for transporting or storing blades} [2023-08] WARNING
|
| F03D 13/402 | . . | {for transporting or storing towers} [2023-08] WARNING
|
| F03D 13/403 | . . | {for transporting or storing nacelles} [2023-08] WARNING
|
| F03D 15/00 | Transmission of mechanical power [2023-08] WARNING
|
F03D 15/05 | . | {using hollow exhausting blades} [2016-05] |
| F03D 15/10 | . | using gearing not limited to rotary motion, e.g. with oscillating or reciprocating members [2023-08] WARNING
|
| F03D 15/101 | . . | {of the epicyclic or planetary type} [2023-08] WARNING
|
F03D 15/15 | . . | {Changing or adjusting stroke} [2017-02] |
F03D 15/20 | . | Gearless transmission, i.e. direct-drive [2017-02] |
| F03D 15/201 | . | {using friction drives, e.g. belts} [2023-08] WARNING
|
| F03D 15/202 | . | {using hydraulic transmission} [2023-08] WARNING
|
| F03D 15/205 | . | {to the generator located at the tower bottom} [2023-08] WARNING
|
| F03D 15/207 | . | {to multiple generators, e.g. in series} [2023-08] WARNING
|
| F03D 17/00 | Monitoring or testing of wind motors, e.g. diagnostics (testing during commissioning of wind motors F03D 13/30) [2023-08] WARNING
|
| F03D 17/001 | . | {Inspection} [2023-08] WARNING
|
| F03D 17/002 | . . | {by testing or performing a safety check} [2023-08] WARNING
|
| F03D 17/003 | . . | {characterised by using optical devices, e.g. lidar or cameras} [2023-08] WARNING
|
F03D 17/004 | . . | {by using remote inspection vehicles, e.g. robots or drones} [2023-08] |
| F03D 17/005 | . | {using computation methods, e.g. neural networks} [2023-08] WARNING
|
F03D 17/006 | . . | {Estimation methods} [2023-08] |
F03D 17/0065 | . . | {for diagnostics} [2023-08] |
| F03D 17/007 | . | {Wind farm monitoring} [2023-08] WARNING
|
| F03D 17/008 | . . | {through wake analysis} [2023-08] WARNING
|
| F03D 17/009 | . | {characterised by the purpose} [2023-08] WARNING
|
| F03D 17/011 | . . | {for monitoring mechanical loads or assessing fatigue; for monitoring structural integrity} [2023-08] WARNING
|
| F03D 17/012 | . . | {for monitoring wear or clearance} [2023-08] WARNING
|
| F03D 17/013 | . . | {for detecting abnormalities or damage} [2023-08] WARNING
|
F03D 17/014 | . . . | {indicative of a fault or failure} [2023-08] |
| F03D 17/015 | . . | {for monitoring vibrations} [2023-08] WARNING
|
| F03D 17/016 | . . . | {indicative of rotor imbalance} [2023-08] WARNING
|
| F03D 17/017 | . . . | {Natural frequencies or oscillations} [2023-08] WARNING
|
| F03D 17/018 | . . | {for monitoring temperature} [2023-08] WARNING
|
| F03D 17/021 | . . | {for monitoring power or current} [2023-08] WARNING
|
| F03D 17/022 | . . | {for monitoring displacement} [2023-08] WARNING
|
| F03D 17/024 | . . | {for monitoring sound or acoustic signals} [2023-08] WARNING
|
| F03D 17/025 | . . | {for calibrating} [2023-08] WARNING
|
| F03D 17/026 | . . | {for assessing power production capabilities} [2023-08] WARNING
|
| F03D 17/027 | . | {characterised by the component being monitored or tested} [2023-08] WARNING
|
| F03D 17/028 | . . | {Blades} [2023-08] WARNING
|
| F03D 17/0285 | . . . | {Surfaces thereof} [2023-08] WARNING
|
| F03D 17/029 | . . | {Blade pitch or yaw drive systems, e.g. pitch or yaw angle} [2023-08] WARNING
|
| F03D 17/031 | . . | {Shafts} [2023-08] WARNING
|
| F03D 17/032 | . . | {Bearings} [2023-08] WARNING
|
| F03D 17/033 | . . | {Gearboxes} [2023-08] WARNING
|
| F03D 17/034 | . . | {Towers} [2023-08] WARNING
|
| F03D 17/036 | . . | {Generators} [2023-08] WARNING
|
| F03D 80/00 | Details, components or accessories not provided for in groups F03D 1/00 - F03D 17/00 [2023-08] WARNING
|
| F03D 80/001 | . | {Human safety arrangements, e.g. evacuation or emergency} [2023-08] WARNING
|
| F03D 80/002 | . | {Micro-siting, i.e. process through which the specific location or arrangement of wind turbine is determined} [2023-08] WARNING
|
| F03D 80/003 | . | {Power-supply to auxiliary components, e.g. to pitch drives or cooling fans} [2023-08] WARNING
|
| F03D 80/004 | . | {for reducing adverse effects on animals, e.g. preventing avian collisions; Detection of animals} [2023-08] WARNING
|
| F03D 80/005 | . | {for reducing noise pollution} [2023-08] WARNING
|
| F03D 80/011 | . | {Decommissioning} [2023-08] WARNING
|
| F03D 80/10 | . | Arrangements for warning air traffic [2023-08] WARNING
|
F03D 80/20 | . | Arrangements for avoiding shadow flicker [2017-02] |
| F03D 80/30 | . | Lightning protection [2023-08] WARNING
|
| F03D 80/301 | . . | {Lightning receptor and down conductor systems in or on blades} [2023-08] WARNING
|
| F03D 80/40 | . | Ice detection; De-icing means [2023-08] WARNING
|
| F03D 80/401 | . . | {De-icing by electrical resistance heating} [2023-08] WARNING
|
| F03D 80/402 | . . | {De-icing by convective heating} [2023-08] WARNING
|
| F03D 80/403 | . . | {Inducing vibrations for de-icing; De-icing by shaking} [2023-08] WARNING
|
| F03D 80/405 | . . | {Ice detection} [2023-08] WARNING
|
| F03D 80/50 | . | Maintenance or repair [2023-08] WARNING
|
| F03D 80/501 | . . | {by using platforms} [2023-08] WARNING
|
| F03D 80/502 | . . | {of rotors or blades} [2023-08] WARNING
|
| F03D 80/504 | . . | {of powertrains, e.g. main shafts or generators} [2023-08] WARNING
|
| F03D 80/505 | . . | {Locking rotors in position} [2023-08] WARNING
|
| F03D 80/507 | . . | {Retrofitting; Repurposing, i.e. reusing of wind motor parts for different purposes; Upgrading, i.e. replacing parts for improving the wind turbine performance} [2023-08] WARNING
|
| F03D 80/509 | . . | {Maintenance scheduling} [2023-08] WARNING
|
| F03D 80/55 | . . | WARNING
|
| F03D 80/60 | . | Cooling or heating of wind motors [2023-08] WARNING
|
| F03D 80/601 | . . | {using ambient airflow; Convective cooling of components} [2023-08] WARNING
|
| F03D 80/602 | . . | {Heat transfer circuits; Refrigeration circuits} [2023-08] WARNING
|
| F03D 80/70 | . | Bearing or lubricating arrangements [2023-08] WARNING
|
| F03D 80/701 | . . | {Pitch or yaw bearings} [2023-08] WARNING
|
| F03D 80/703 | . . | {Shaft bearings} [2023-08] WARNING
|
| F03D 80/705 | . . | {Lubrication circuits; Lubrication delivery means} [2023-08] WARNING
|
F03D 80/707 | . . . | {Gearing lubrication, e.g. gear boxes} [2023-08] |
F03D 80/709 | . . . | {Bearing lubrication} [2023-08] |
F03D 80/80 | . | Arrangement of components within nacelles or towers [2017-02] |
| F03D 80/82 | . . | {of electrical components} [2023-08] WARNING
|
| F03D 80/821 | . . . | {within nacelles} [2023-08] WARNING
|
| F03D 80/85 | . . . | {Cabling} [2023-08] WARNING
|
| F03D 80/88 | . . | {of mechanical components} [2023-08] WARNING
|
| F03D 80/881 | . . . | {within nacelles} [2023-08] WARNING
|