Version: 2025.01
Loading Scheme...
| H02B 1/00 | Frameworks, boards, panels, desks, casings; Details of substations or switching arrangements [2022-08] |
H02B 1/01 | . | Frameworks [2013-01] |
H02B 1/011 | . . | {Open support bases} [2013-01] |
H02B 1/012 | . . | {Details of mechanical connections} [2013-01] |
H02B 1/013 | . . | {Profiles for cabinet frames} [2013-01] |
H02B 1/014 | . . | {Corner connections for frameworks} [2013-01] |
H02B 1/015 | . | Boards, panels, desks; Parts thereof or accessories therefor [2013-01] |
H02B 2001/0155 | . . | {Removable shutters for non-used openings} [2013-01] |
H02B 1/03 | . . | for energy meters [2013-01] |
H02B 1/04 | . . | Mounting thereon of switches or of other devices in general, the switch or device having, or being without, casing [2013-01] |
H02B 1/041 | . . . | {Mechanical coupling for side-by-side mounted apparatus} [2013-01] |
H02B 1/042 | . . . | {Mounting on perforated supports by means of screws or locking members} [2013-01] |
H02B 1/043 | . . . . | {the perforated support having openings distributed according to a pattern} [2013-01] |
H02B 1/044 | . . . | Mounting through openings [2013-01] |
H02B 1/048 | . . . . | Snap mounting [2013-01] |
H02B 1/052 | . . . | Mounting on rails [2013-01] |
H02B 1/0523 | . . . . | {locked into position by a sliding member} [2013-01] |
H02B 1/0526 | . . . . | {locking or releasing devices actuated from the front face of the apparatus} [2013-01] |
H02B 1/056 | . . . | Mounting on plugboards [2013-01] |
H02B 1/0565 | . . . . | {by means of an adapter carrying one or more apparatuses (holders with sockets H01R 33/00)} [2013-01] |
H02B 1/06 | . . | having associated enclosures, e.g. for preventing access to live parts [2023-02] |
H02B 1/063 | . . . | {with tamper resistant sealing device} [2013-01] |
H02B 1/066 | . . . | {with hinged covers (covers for distribution boxes H02G 3/14)} [2013-01] |
H02B 1/14 | . | Shutters or guards for preventing access to contacts (shielding of isolating-contacts in withdrawable switchgear H02B 11/24) [2013-01] |
H02B 1/16 | . | Earthing arrangements (earthing arrangements for substations H02B 5/01; earthing arrangements for switchgear H02B 11/28, H02B 13/075) [2023-02] |
H02B 1/18 | . | Disposition or arrangement of fuses (for switchgear having a withdrawable carriage H02B 11/26) [2013-01] |
H02B 1/20 | . | Bus-bar or other wiring layouts, e.g. in cubicles, in switchyards (installations of bus-bars H02G 5/00) [2017-08] |
H02B 1/202 | . . | {Cable lay-outs} [2013-01] |
H02B 1/205 | . . | {for connecting electrical apparatus mounted side by side on a rail} [2013-01] |
H02B 1/207 | . . | {Cross-bar layouts} [2013-01] |
H02B 1/21 | . . | Bus-bar arrangements for rack-mounted devices with withdrawable units [2013-01] |
H02B 1/22 | . . | Layouts for duplicate bus-bar selection [2013-01] |
H02B 1/24 | . | Circuit arrangements for boards or switchyards [2023-02] |
| H02B 1/26 | . |
H02B 1/28 | . . | dustproof, splashproof, drip-proof, waterproof or flameproof [2013-01] |
H02B 1/30 | . . | Cabinet-type casings; Parts thereof or accessories therefor [2013-01] |
H02B 1/301 | . . . | {mainly consisting of a frame onto which plates are mounted} [2013-01] |
H02B 1/303 | . . . | {Bases or feet} [2013-01] |
H02B 1/305 | . . . | {Cable entries} [2013-01] |
H02B 1/306 | . . . | {Accessories, e.g. windows} [2013-01] |
H02B 1/308 | . . . | {Mounting of cabinets together} [2013-01] |
H02B 1/32 | . . . | Mounting of devices therein [2013-01] |
H02B 1/34 | . . . . | Racks [2013-01] |
H02B 1/36 | . . . . . | with withdrawable units [2013-01] |
H02B 1/38 | . . . | Hinged covers or doors [2013-01] |
H02B 1/40 | . . | Wall-mounted casings; Parts thereof or accessories therefor [2013-01] |
H02B 1/42 | . . . | Mounting of devices therein [2013-01] |
H02B 1/44 | . . . | Hinged covers or doors [2013-01] |
H02B 1/46 | . . | Boxes; Parts thereof or accessories therefor [2013-01] |
H02B 1/48 | . . . | Mounting of devices therein [2013-01] |
H02B 1/50 | . . | Pedestal- or pad-mounted casings; Parts thereof or accessories therefor [2013-01] |
H02B 1/505 | . . . | {retractable installations} [2013-01] |
H02B 1/52 | . . | Mobile units, e.g. for work sites [2013-01] |
H02B 1/54 | . | Anti-seismic devices or installations [2023-02] |
H02B 1/56 | . | Cooling; Ventilation [2013-01] |
H02B 1/565 | . . | {for cabinets} [2013-01] |
H02B 3/00 | Apparatus specially adapted for the manufacture, assembly, or maintenance of boards or switchgear [2013-01] |
H02B 5/00 | Non-enclosed substations; Substations with enclosed and non-enclosed equipment [2013-01] |
H02B 5/01 | . | Earthing arrangements, e.g. earthing rods [2013-01] |
H02B 5/02 | . | mounted on pole, e.g. pole transformer substation [2013-01] |
H02B 5/06 | . | gas-insulated [2013-01] |
H02B 7/00 | Enclosed substations, e.g. compact substations [2013-01] |
H02B 11/00 | Switchgear having carriage withdrawable for isolation [2013-01] |
H02B 11/02 | . | Details [2013-01] |
H02B 11/04 | . . | Isolating-contacts, e.g. mountings or shieldings [2023-02] |
H02B 11/06 | . . | Means for duplicate bus-bar selection [2023-02] |
H02B 11/08 | . . | Oil-tank lowering means associated with withdrawal mechanism [2013-01] |
H02B 11/10 | . . | Indicating electrical condition of gear; Arrangement of test sockets [2013-01] |
H02B 11/12 | . | with isolation by horizontal withdrawal [2013-01] |
H02B 11/18 | . | with isolation by vertical withdrawal [2013-01] |
H02B 11/20 | . . | having an enclosure [2013-01] |
H02B 11/22 | . . . | wherein front of enclosure moves with carriage upon horizontal withdrawal subsequent to isolation [2013-01] |
H02B 11/24 | . | Shutters or guards [2013-01] |
H02B 11/26 | . | Arrangements of fuses, resistors, voltage arresters or the like [2013-01] |
H02B 11/28 | . | Earthing arrangements [2013-01] |
H02B 13/00 | Arrangement of switchgear in which switches are enclosed in, or structurally associated with, a casing, e.g. cubicle (switchgear having carriage withdrawable for isolation H02B 11/00) [2023-02] |
H02B 13/005 | . | {Electrical connection between switchgear cells} [2013-01] |
H02B 13/01 | . | with resin casing [2013-01] |
H02B 13/02 | . | with metal casing [2013-01] |
H02B 13/025 | . . | Safety arrangements, e.g. in case of excessive pressure or fire due to electrical defect [2023-02] |
H02B 13/035 | . . | Gas-insulated switchgear [2013-01] |
H02B 13/0352 | . . . | {for three phase switchgear} [2013-01] |
H02B 13/0354 | . . . | {comprising a vacuum switch (H02B 13/0352 takes precedence)} [2013-01] |
H02B 13/0356 | . . . | {Mounting of monitoring devices, e.g. current transformers} [2013-01] |
H02B 13/0358 | . . . | {Connections to in or out conductors (connectors in general H01R)} [2013-01] |
H02B 13/045 | . . . | Details of casing, e.g. gas tightness [2023-02] |
H02B 13/055 | . . . | Features relating to the gas [2023-02] |
H02B 13/065 | . . . | Means for detecting or reacting to mechanical or electrical defects [2023-02] |
H02B 13/0655 | . . . . | {through monitoring changes of gas properties} [2013-01] |
H02B 13/075 | . . . | Earthing arrangements [2013-01] |
H02B 13/08 | . | with stone, brick or concrete casing [2013-01] |
H02B 15/00 | Supervisory desks or panels for centralised control or display [2023-02] |
H02B 15/02 | . | with mimic diagrams [2013-01] |
H02B 15/04 | . . | consisting of building blocks [2013-01] |
H02B 99/00 | Subject matter not provided for in other groups of this subclass [2022-08] |