![]() | INSTALLATION OF ELECTRIC CABLES OR LINES, OR OF COMBINED OPTICAL AND ELECTRIC CABLES OR LINES ( distribution points incorporating switches H02B; guiding telephone cords H04M 1/15 ; cable ducts or mountings for telephone or telegraph exchange installations H04Q 1/06 ) NOTE -
|
![]() | Methods or apparatus specially adapted for installing, maintaining, repairing or dismantling electric cables or lines |
H02G 1/005 | . | { for cutting cables or wires, or splicing } |
![]() | . | for overhead lines or cables |
H02G 1/04 | . . | for mounting or stretching ( wire stretchers in general B25B 25/00 ) |
![]() | . | for laying cables, e.g. laying apparatus on vehicle ( combined with trench digging or back-filling machines or dredgers E02F 5/00 ) |
![]() | . . | through tubing or conduit, e.g. rod or draw wire for pushing or pulling { ( inserting electrical cables into tubes using wallbores E21B 17/206 ; for optical cables G02B 6/4401 ) } |
H02G 1/081 | . . . | { using pulling means at cable ends, e.g. pulling eyes or anchors } |
H02G 1/083 | . . . | { using lines, e.g. needles, rods or tapes } |
H02G 1/085 | . . . | { using portable tools } |
H02G 1/086 | . . . | { using fluid as pulling means, e.g. liquid, pressurised gas or suction means } |
H02G 1/088 | . . . | { using pulling devices movable inside conduits } |
H02G 1/10 | . . | in or under water |
![]() | . |
![]() | H02G 1/1202 | . . | { by cutting and withdrawing insulation } |
![]() | H02G 1/1204 | . . . | { Hand-held tools } |
![]() | . . . . | { the cutting element not rotating about the wire or cable ( making longitudinal and transverse or helical cut H02G 1/1229 ) } |
![]() | H02G 1/1209 | . . . . . | { making a transverse cut } |
H02G 1/1212 | . . . . . . | { using wire or cable clamping means } |
H02G 1/1214 | . . . . . . | { not using wire or cable clamping means } |
H02G 1/1217 | . . . . . | { making a longitudinal cut } |
![]() | . . . . | { the cutting element rotating about the wire or cable ( making longitudinal and transverse or helical cut H02G 1/1229 ) } |
![]() | H02G 1/1229 | . . . . | { the cutting element making a longitudinal, and a transverse or a helical cut } |
H02G 1/1231 | . . . . . | { using a swivelling cutting element } |
H02G 1/1234 | . . . . . | { the tool being of the plier type } |
![]() | H02G 1/1236 | . . . . | { Features relating to cutting elements } |
![]() | H02G 1/1248 | . . . | { Machines } |
![]() | . . . . | { the cutting element not rotating about the wire or cable ( making longitudinal and transverse or helical cut H02G 1/1268 ) } |
![]() | H02G 1/1253 | . . . . . | { making a transverse cut } |
H02G 1/1256 | . . . . . . | { using wire or cable-clamping means } |
H02G 1/1258 | . . . . . . | { not using wire or cable-clamping means } |
H02G 1/126 | . . . . . | { making a longitudinal cut } |
H02G 1/1265 | . . . . | { the cutting element rotating about the wire or cable ( making longitudinal and transverse or helical cut H02G 1/1268 ) } |
H02G 1/1268 | . . . . | { the cutting element making a longitudinal in combination with a transverse or a helical cut } |
H02G 1/127 | . . . . | { Features relating to cutting elements } |
H02G 1/1273 | . . | { by pushing backwards insulation } |
![]() | H02G 1/1275 | . . | { by applying heat } |
H02G 1/1278 | . . . | { using heated blades } |
H02G 1/128 | . . . | { using radiant energy, e.g. a laser beam } |
H02G 1/1282 | . . . | { removing metallic shields } |
H02G 1/1285 | . . | { by friction, e.g. abrading, grinding, brushing } |
H02G 1/1287 | . . | { by means of a solvent } |
H02G 1/129 | . . | { by means of a cryogenic fluid } |
H02G 1/1292 | . . | { Devices for dismantling twisted filaments } |
H02G 1/1295 | . . | { Devices for splitting and dismantling flat cables } |
H02G 1/1297 | . . | { Removing armouring from cables } |
![]() | . | for joining or terminating cables ( joining electric conductors H01R 43/00 ) |
H02G 1/16 | . | for repairing insulation or armouring of cables |
![]() | Installations of electric cables or lines in or on buildings, equivalent structures or vehicles ( installations of bus-bars H02G 5/00 ; overhead installations H02G 7/00 ; installations in or on the ground H02G 9/00 ; channels or vertical ducts for receiving utility lines E04F 17/08 ; wiring of electric apparatus in general H05K ) |
![]() | . | Details |
H02G 3/03 | . . | Cooling |
![]() | . . | Protective tubings or conduits { or channels or other supports } ( pipes or tubings in general F16L ) |
![]() | . . . | { Details thereof ( installation or suspension of conduit channels and other supports H02G 3/263 ) } |
H02G 3/0425 | . . . |
H02G 3/0431 | . . . | { Wall trunking } |
![]() | . . . | { Channels } |
H02G 3/0443 | . . . . | { formed by wire or analogous netting } |
H02G 3/045 | . . . . | { provided with perforations or slots permitting introduction or exit of wires } |
H02G 3/0456 | . . . | { Ladders or other supports } |
![]() | . . . | { Tubings, i.e. having a closed section } |
H02G 3/0468 | . . . . | { Corrugated } |
H02G 3/0475 | . . . . | { formed by a succession of articulated units } |
H02G 3/0481 | . . . . |
H02G 3/0487 | . . . . |
H02G 3/0493 | . . . | { Service poles } |
![]() | . . | Joints for connecting lengths of protective tubing { or channels } , to each other or to casings, e.g. to distribution boxes ; Ensuring electrical continuity in the joint |
H02G 3/0608 | . . . | { Joints for connecting non cylindrical conduits, e.g. channels } |
![]() | H02G 3/0616 | . . . | { Joints for connecting tubing to casing } |
![]() | H02G 3/0625 | . . . . | { with means for preventing disengagement of conductors } |
H02G 3/0633 | . . . . . | { with means urging the conductors to follow a non-straight line } |
H02G 3/0641 | . . . . . | { with means distorted around the conductors } |
H02G 3/065 | . . . . . | { with means biting into the conductor-insulation, e.g. teeth-like elements or gripping fingers ( H02G 3/0675 , H02G 3/0683 take precedence ) } |
H02G 3/0658 | . . . . . | { with means constricting the conductor-insulation ( H02G 3/065 , H02G 3/0675 , H02G 3/0683 take precedence ) } |
H02G 3/0666 | . . . . . |
H02G 3/0675 | . . . . . | { with bolts operating in a direction parallel to the conductors } |
H02G 3/0683 | . . . . . | { with bolts operating in a direction transverse to the conductors } |
H02G 3/0691 | . . . . | { Fixing tubing to casing by auxiliary means co-operating with indentations of the tubing, e.g. with tubing-convolutions } |
![]() | . . | Distribution boxes ; Connection or junction boxes ( cable terminations H02G 15/02 ) |
![]() | . . . | { Bases, casings or covers } |
H02G 3/086 | . . . | { Assembled boxes } |
H02G 3/088 | . . . | { Dustproof, splashproof, drip-proof, waterproof, or flameproof casings or inlets } |
![]() | H02G 3/10 | . . . | for surface mounting on a wall |
![]() | . . . | for flush mounting |
H02G 3/121 | . . . . | { in plain walls } |
![]() | . . . . | { in thin walls } |
H02G 3/125 | . . . . . | { with supporting bar extending between two separate studs of a wall frame } |
H02G 3/126 | . . . . . | { with supporting means for mounting on a single wall stud } |
H02G 3/128 | . . . . | { in plinths, channels, raceways or similar } |
H02G 3/14 | . . . | Fastening of cover or lid to box |
H02G 3/16 | . . . | structurally associated with support for line-connecting terminals within the box ( terminals H01R 9/00 ) |
![]() | . . . | providing line outlets |
H02G 3/22 | . | Arrangements for leading cables or lines through walls, floors, or ceilings, e.g. into building ( devices for use where pipes, cables or protective tubing pass through walls or partitions F16L 5/00 ; lead-in or lead-through insulators H01B 17/26 ; insulating tubes or sleeves H01B 17/58 ) |
H02G 3/24 | . | Installation of lines or cables on walls, ceilings or floors by means of insulators ( insulators H01B 17/00 ) |
![]() | . | Installations of cables, lines, or separate protective tubing therefor directly on or in walls, ceilings, or floors ( by means of insulators H02G 3/24 ; supports for pipes, cables or protective tubing F16L 3/00 ; hose-clips F16L 33/02 ) |
H02G 3/263 | . . | { Installation, e.g. suspension, of conduit channels or other supports } |
H02G 3/266 | . . | { Mounting by adhesive material } |
![]() | . | Installations of cables, lines, or separate protective tubing therefor in conduits or ducts pre-established in walls, ceilings or floors |
![]() | . | Installations of cables or lines on walls, floors or ceilings ( support for pipes, cables or protective tubing F16L 3/00 ; hose clips F16L 33/02 ) |
H02G 3/305 | . . | { Mounting by adhesive material } |
H02G 3/32 | . . | using mounting clamps |
H02G 3/34 | . . | using separate protective tubing |
![]() | . | Installation of cables or lines in walls, floors or ceilings ( 3/22 takes precedence ) |
![]() | Installations of bus-bars |
H02G 5/002 | . | { Joints between bus-bars for compensating thermal expansion } |
H02G 5/005 | . | { Laminated bus-bars } |
H02G 5/007 | . | { Butt joining of bus-bars by means of a common bolt, e.g. splice joint ( electrically conductive connections characterised by contacting members H01R 4/58 ) } |
![]() | H02G 5/02 | . | Open installations |
H02G 5/04 | . | Partially-enclosed installations, e.g. in ducts and adapted for sliding or rolling current collection ( non-rotary current collectors H01R 41/00 ) |
![]() | H02G 5/06 | . | Totally-enclosed installations, e.g. in metal casings |
H02G 5/061 | . . |
![]() | H02G 5/063 | . . | { filled with oil or gas } |
H02G 5/065 | . . . | { Particle traps ( gettering in vacuum switches H01H 33/66E1; in discharge or vacuum tubes H01J 7/18 , H01J 19/70 ) } |
![]() | H02G 5/066 | . . | { Devices for maintaining distance between conductor and enclosure } |
H02G 5/08 | . . | Connection boxes therefor |
H02G 5/10 | . | Cooling |
![]() | Overhead installations of electric lines or cables ( installations of bus-bars H02G 5/00 ; trolley wires or contact lines for electric railways B60M ; fastening conductors to insulators H01B 17/00 , e.g. H01B 17/06 , H01B 17/16 , H01B 17/22 ; protection against abnormal electric conditions H01H ; hook contacts for temporary connections to overhead lines H01R 11/14 ) |
H02G 7/02 | . | Devices for adjusting or maintaining mechanical tension, e.g. take-up device |
H02G 7/04 | . | Arrangements or devices for relieving mechanical tension |
![]() | . | Suspension arrangements or devices for electric cables or lines |
![]() | . | Suspensions for lines or cables along a separate supporting wire, e.g. S-hook |
H02G 7/08 | . . | Members clamped to the supporting wire or to the line or cable |
H02G 7/10 | . . | Flexible members or lashings wrapped around both the supporting wire and the line or cable |
![]() | . | Devices for maintaining distance between parallel conductors, e.g. spacer |
H02G 7/14 | . | Arrangements or devices for damping mechanical oscillations of lines, e.g. for reducing production of sound { ( damping spacers H02G 7/125 ) } |
H02G 7/16 | . | Devices for removing snow or ice from lines or cables ( from insulators H01B 17/52 ) |
H02G 7/18 | . | Devices affording mechanical protection in the event of breakage of a line or cable, e.g. net for catching broken lines |
![]() | . | Spatial arrangements or dispositions of lines or cables on poles, posts, or towers ( construction of poles, posts or towers E04H 12/22 ) |
H02G 7/22 | . | Arrangements of earthing wires suspended between mastheads |
![]() | Installations of electric cables or lines in or on the ground or water ( cathodic protection C23F 13/02 ; detection of buried cables G01V ) |
![]() | . | laid directly in or on the ground, river-bed or sea-bottom ; Coverings therefor, e.g. tile |
H02G 9/04 | . | in surface ducts ; Ducts or covers therefor |
![]() | . | in underground tubes or conduits ; Tubes or conduits therefor |
H02G 9/08 | . | in tunnels |
H02G 9/10 | . | in cable chambers, e.g. in manhole, in handhole ( building aspects of cable chambers Section E, e.g. E04H 5/06 ) |
H02G 9/12 | . | supported on or from floats, e.g. in water ( floating cables H01B 7/12 ) |
![]() | Arrangements of electric cables or lines between relatively-movable parts ( { storing means for coiled material specially adapted for repeatedly paying-out and re-storing length of material for particular purposes B65H 75/34 } ; current collectors H01R ; { winding-up telephone cord H04M 1/15 } ) |
H02G 11/003 | . | { using gravity-loaded or spring-loaded loop } |
H02G 11/006 | . | { using extensible carrier for the cable, e.g. self-coiling spring ( extensible conductors or cables H01B 7/06 ) } |
H02G 11/02 | . | using take-up reel or drum |
![]() | Installations of lightning conductors ; Fastening thereof to supporting structure ( indicating, counting or recording lightning strokes G01; lightning arrestors H01C 7/12 , H01C 8/04 , H01G 9/18 , H01T; earth plates, pins or other contacts H01R ) WARNING -
|
H02G 13/20 | . | { Active discharge triggering } |
H02G 13/40 | . | { Connection to earth } |
H02G 13/60 | . | { Detecting; Measuring; Sensing; Testing; Simulating } |
H02G 13/80 | . | { Discharge by conduction or dissipation, e.g. rods, arresters, spark gaps } |
![]() | Cable fittings |
H02G 15/003 | . | { Filling materials, e.g. solid or fluid insulation } |
H02G 15/007 | . | Devices for relieving mechanical stress |
H02G 15/013 | . | Sealing means for cable inlets ( inlets for cables filled with, or surrounded by, gas or oil H02G 15/32 ) |
![]() | . | Cable terminations ( for gas- or oil-filled cables H02G 15/22 ) |
H02G 15/025 | . . | { for coaxial cables or hollow conductors ( connections between HF conductors H01P 1/04 ; plug and socket connections per se H01R 24/38 ) } |
![]() | H02G 15/04 | . . | Cable-end sealings |
![]() | . . | Cable terminating boxes, frames, or other structures ( terminal blocks H01R 9/00 ) |
![]() | H02G 15/064 | . . . | with devices for relieving electrical stress |
H02G 15/068 | . . . . | connected to the cable shield only ( H02G 15/072 takes precedence ) |
H02G 15/072 | . . . . | of the condenser type |
H02G 15/076 | . . . | for multi-conductor cables |
![]() | . | Cable junctions ( for gas- or oil-filled cables H02G 15/24 ; disconnectible junctions, electrical connections H01R ) |
H02G 15/085 | . . | { for coaxial cables or hollow conductors ( plug and socket connections between HF conductors H01P 1/04 ; plug and socket connections per se H01R 24/38 ) } |
![]() | . . |
![]() | H02G 15/103 | . . . | with devices for relieving electrical stress |
![]() | . . . . | connected to the cable shield only ( H02G 15/107 takes precedence ) |
H02G 15/107 | . . . . | of the condenser type |
H02G 15/113 | . . . | Boxes split longitudinally in main cable direction |
H02G 15/115 | . . . | Boxes split perpendicularly to main cable direction |
H02G 15/117 | . . . | for multiconductor cables |
![]() | H02G 15/12 | . . . | for incorporating transformers, loading coils or amplifiers |
H02G 15/16 | . . . | structurally associated with support for line-connecting terminals within the box |
![]() | . . | protected by sleeves, e.g. for communication cable ( two-part covers H02G 15/10 ; { preforms having internal stresses B29C 61/00 } ) |
![]() | . . . | { Heat shrinkable sleeves ( insulation of electrical connections using a heat shrinking insulating sleeve H01R 4/72 ) } |
![]() | H02G 15/182 | . . . | { held in expanded condition in radial direction prior to installation } |
![]() | H02G 15/184 | . . . | with devices for relieving electrical stress |
H02G 15/192 | . . . | with support means for ends of the sleeves |
H02G 15/196 | . . . | having lapped insulation |
![]() | . | Cable fittings for cables filled with or surrounded by gas or oil ( H02G 15/34 takes precedence ) |
H02G 15/205 | . . | { for coaxial cables } |
![]() | H02G 15/22 | . . | Cable terminations |
![]() | H02G 15/24 | . . | Cable junctions |
H02G 15/26 | . . | Expansion vessels ; Locking heads ; Auxiliary pipe-lines |
H02G 15/28 | . . | structurally associated with devices for indicating the presence or location of non-electric faults ( combined with electric protective means H02H ) |
H02G 15/30 | . . | with devices for relieving electrical stress |
H02G 15/32 | . . | Cable inlets |
H02G 15/34 | . |
![]() | H02G 2001/00 | Methods or apparatus specially adapted for installing, maintaining, repairing or dismantling electric cables or lines |
![]() | H02G 2001/12 | . |
![]() | H02G 2001/1202 | . . | { by cutting and withdrawing insulation } |
![]() | H02G 2001/1204 | . . . | { Hand-held tools } |
![]() | H02G 2001/1207 | . . . . | { the cutting element not rotating about the wire or cable ( making longitudinal and transverse or helical cut H02G 1/1229 ) } |
![]() | H02G 2001/1248 | . . . | { Machines } |
![]() | H02G 2001/1251 | . . . . | { the cutting element not rotating about the wire or cable ( making longitudinal and transverse or helical cut H02G 1/1268 ) } |
![]() | H02G 2200/00 | Indexing scheme relating to installation of electric cables or lines covered by H02G |