This page requires javascipt to function properly
2 . (1 indent ) Destination controlled by operator at remote site
3 . (1 indent ) Destination controlled by sensed condition
4 .. (2 indent ) Controlled by coded load
5 ... (3 indent ) Magnetic material on load
6 ... (3 indent ) Electrical contact on load
7 ... (3 indent ) Adjustable or changeable code on load
8 ... (3 indent ) Presence or size of recess or protrusion on front of load
9 .... (4 indent ) Protrusion
10 WITH MEANS TO CONTROL CONVEYING FLUID OR MOVEMENT OF LOAD IN RESPONSE TO SENSED CONDITION
11 . (1 indent ) Responsive to obstacle in system
12 . (1 indent ) Control of conveying fluid
13 .. (2 indent ) Reversing of fluid current in single tube system
14 .. (2 indent ) Responsive to velocity or pressure change in conveying fluid
15 ... (3 indent ) To initiate or terminate fluid current
16 .... (4 indent ) In response to introduction or discharge of load
17 .... • (5 indent ) Discharge and introduction
18 .... • (5 indent ) With timer to terminate fluid current
19 .. (2 indent ) Responsive to presence or absence or quantity of load
20 ... (3 indent ) With stepped reset for each load article introduced at intake
21 ... (3 indent ) With load detector at outlet to terminate fluid current
22 ... (3 indent ) With timer to terminate current
23 ... (3 indent ) Level or weight of load in receptacle
24 .... (4 indent ) At intake
25 .... • (5 indent ) And control of load input to receptacle
26 .. (2 indent ) Responsive to movement of gate to initiate or terminate fluid current
27 ... (3 indent ) To closure of intake gate to initiate fluid current
28 . (1 indent ) Control of load input or output
30 ... (3 indent ) Responsive to pressure or velocity change of conveying fluid
31 ... (3 indent ) Responsive to presence, absence, or quantity of load
32 .... (4 indent ) Level or weight of load in receptacle
33 .... • (5 indent ) In receptacle at discharge
34 WITH SIGNAL, INDICATOR, OR INSPECTION MEANS
36 . (1 indent ) With load motion observing means
37 . (1 indent ) Coded carrier
39 . (1 indent ) Vehicle mounted
40 .. (2 indent ) Plural vehicles
41 .. (2 indent ) Towed vehicle
42 .. (2 indent ) Power takeoff
43 .. (2 indent ) With storage means on vehicle for fluid conveyor components
44 .. (2 indent ) With auxiliary supporting means
45 WITH MEANS TO PREVENT PIPELINE SLUMPING
46 WITH ADJUNCTIVE SUBSTANCE ADDED
51 WITH DIVERSE POWER-DRIVEN CONVEYOR
54 ... (3 indent ) With material recirculating screw
55 ... (3 indent ) Including means to fluidize material
56 ... (3 indent ) Feeding to fluid conveyor inlet
57 .... (4 indent ) Feeds to inlet of blower or pump
58 .... • (5 indent ) Screw axis coaxial with axis of rotary blower or pump
59 .... • (5 indent ) Plural screws
60 .... (4 indent ) With check valve between screw and fluid current conveyor
61 .... (4 indent ) Fluid jet at conveyor inlet
62 .. (2 indent ) Successively registering pockets
63 ... (3 indent ) Input to fluid conveyor
64 .... (4 indent ) With venting of pockets
65 .... (4 indent ) Having radial blades
66 .... • (5 indent ) Rotatable about vertical axis
67 .... • (5 indent ) Fluid flow discharges pockets
68 .... (4 indent ) Peripheral pockets formed on rotating member
71 .. (2 indent ) Thrower
72 . (1 indent ) Magazine
73 . (1 indent ) Reciprocating or oscillating
74 .. (2 indent ) With pocket
75 .. (2 indent ) Vibrating
78 .. (2 indent ) Permeable belt
79 .. (2 indent ) At inlet to fluid conveyor
80 ... (3 indent ) Feeds to intake of blower or pump
81 ... (3 indent ) Pushers, buckets, or tines
82 .. (2 indent ) At outlet to fluid conveyor
83 WITH LOAD BRAKING OR RETARDING MEANS
84 . (1 indent ) Utilizing a fluid
86 HAVING MEANS FOR MAINTAINING LOAD IN SUSPENSION ALONG FLOW PATH
87 . (1 indent ) With load orienting means
88 . (1 indent ) By load supporting jets
89 . (1 indent ) Including permeable member
90 .. (2 indent ) In receptacle
91 ... (3 indent ) Permeable member surrounding discharge opening or conduit
92 . (1 indent ) By fluid whirling action
93 HAVING MEANS TO INTRODUCE BOOSTER FLUID INTO CONVEYOR
94 . (1 indent ) Plural booster inputs
95 .. (2 indent ) With parallel fluid supply conduit
96 BLOWER OR PUMP HAVING LOAD INTAKE OPENING IN HOUSING
97 . (1 indent ) Including load or blower protecting means
98 . (1 indent ) Having separate opening in housing for conveying fluid input
100 .. (2 indent ) Having radially extending blades
101 ... (3 indent ) Mounted on axial face of a disc
102 ... (3 indent ) With load receptacle feeding to intake of blower or pump
103 .... (4 indent ) Blower or pump housing movably mounted relative to receptacle
104 .... (4 indent ) Plural blowers or pumps
105 HAVING LOAD BY-PASS AROUND BLOWER OR PUMP
106 ENDLESS FLUID CURRENT PATH
107 MATERIAL-BACKFLOW DISCHARGE
108 INTAKE TO FLUID CURRENT CONVEYOR
109 . (1 indent ) Combined intake and discharge
110 .. (2 indent ) With terminal
111 ... (3 indent ) Captive carrier
112 ... (3 indent ) Single inlet-outlet
113 . (1 indent ) Movable inlet
114 .. (2 indent ) Follows load level
115 .. (2 indent ) Reciprocating or swinging
116 ... (3 indent ) Having telescoping intake
117 . (1 indent ) Conveyor having plural intakes
118 .. (2 indent ) From receptacle
119 ... (3 indent ) Having plural compartments
120 ... (3 indent ) Plural receptacles
121 . (1 indent ) With sifter
122 . (1 indent ) Load receptacle type
123 .. (2 indent ) Having inlets to separate conveyors
124 .. (2 indent ) Plural receptacles in series
125 ... (3 indent ) With gate valve between receptacles
126 ... (3 indent ) With conical plug valve between receptacles
127 .. (2 indent ) With valve between receptacle and fluid conveyor
128 ... (3 indent ) Reciprocating, rotating, or swinging
129 .... (4 indent ) Rotatable hollow cylinder type
130 .... (4 indent ) Gate type
131 .... • (5 indent ) Pivotable
132 .... (4 indent ) Vertically movable
133 .... • (5 indent ) Sleeve or conduit
134 .. (2 indent ) With means to agitate load in receptacle
135 ... (3 indent ) Rotary
136 ... (3 indent ) Fluid
138 .... (4 indent ) Passed through permeable member
139 .. (2 indent ) Blower or pump carried by receptacle
140 ... (3 indent ) Plural blowers or pumps
141 .. (2 indent ) Inlet conduit extending downwardly inside receptacle
142 ... (3 indent ) With conduit supplying lifting fluid to interior of receptacle
143 .... (4 indent ) Fluid supplying conduit extends to inlet conduit
144 .. (2 indent ) Conveying fluid velocity altered at load input
145 .. (2 indent ) Having connection for external suction or pressure source
146 .. (2 indent ) Conveying fluid introduced under pressure to interior of receptacle
147 . (1 indent ) Terminal type
148 .. (2 indent ) Intake gate
149 ... (3 indent ) With gate lock
150 ... (3 indent ) Serially arranged gates
151 . (1 indent ) Upstream of suction source
152 .. (2 indent ) Including specific intake nozzle structure
153 .. (2 indent ) Suction induced by pressure stream
154 FLUID CURRENT CONVEYOR OUTLET MEANS
155 . (1 indent ) Conveyor having plural outlets
156 .. (2 indent ) Feeding plural receptacles
157 . (1 indent ) Deflector
158 .. (2 indent ) Telescoping
159 .. (2 indent ) Pivoted
160 ... (3 indent ) Adjustable
161 .... (4 indent ) From remote location
162 .. (2 indent ) Rotatable
163 .. (2 indent ) Carried by receptacle
164 . (1 indent ) Movable outlet
165 .. (2 indent ) Horizontally swinging
166 ... (3 indent ) And vertically swinging
167 .. (2 indent ) Telescoping
168 . (1 indent ) With material separating receptacle
169 .. (2 indent ) Having air lock
170 .. (2 indent ) Having plural inputs
171 .. (2 indent ) Having filter
172 ... (3 indent ) And means to clean filter
173 .. (2 indent ) Cyclone separator
174 .. (2 indent ) Conveyor outlet conduit extending upwardly inside receptacle
175 .. (2 indent ) And upstream pressure source
176 . (1 indent ) Having terminal
177 .. (2 indent ) With gate and means to open gate prior to article or carrier arrival
178 ... (3 indent ) Serially arranged gates
179 .. (2 indent ) Upward delivery
180 .. (2 indent ) Discharge gate
181 LOAD FLOW DIVERTER, DIVIDER, OR COMBINER
182 . (1 indent ) Movable conduit section
183 . (1 indent ) Movable valve in conduit
185 . (1 indent ) Wheeled
186 . (1 indent ) Having side opening
187 . (1 indent ) Having end opening
188 .. (2 indent ) With closure for end opening
189 ... (3 indent ) Removable
190 . (1 indent ) With conduit engaging seal or bumper structure
192 . (1 indent ) With fluid valve or load spacer
193 . (1 indent ) With wear protection means
194 . (1 indent ) Having fluid nozzle
195 . (1 indent ) Having changing cross section
196 . (1 indent ) Flexible
FOR000 CLASS-RELATED FOREIGN DOCUMENTS
Note: Some content
linked to on this page may require a plug-in for Adobe
Acrobat Reader .
This file produced by USPTO - SIRA -
Office of Patent Automation - ReferenceTools Project.
Questions or comments relating to this file should be
directed to Patent
Automation Feedback .