This page requires javascipt to function properly
1 WITH DIVERSE ART-TYPE DEVICE
2 WITH SEPARATE DISTINCT DIVERSE ART-TYPE SWITCHING DEVICE (E.G., FLUID- OR MECHANICAL-ACTUATED)
3 . (1 indent ) Bimetallic device with other
4 . (1 indent ) Fusible element device with other
5 .. (2 indent ) Diverse art-type switching device responsive to the condition of fusible element
6 .. (2 indent ) With automatic circuit-interrupting device
7 ... (3 indent ) Multiphase of multipole
8 .. (2 indent ) Manually operable mechanical device
9 ... (3 indent ) Knife or blade switch
10 ... (3 indent ) Rotary or reciprocating mechanism
11 .. (2 indent ) With multiple circuit connector device (e.g., multiple mechanical)
12 WITH DIVERSE ART-TYPE ACTUATOR FOR SINGLE SWITCH
13 . (1 indent ) Bimetallic with other
14 ELECTROTHERMALLY ACTUATED SWITCHES
15 . (1 indent ) Shunt or short circuit completion devices
16 .. (2 indent ) Bimetallic means
17 .. (2 indent ) Fusible material combined with gap
18 ... (3 indent ) Gaseous space discharge gap (e.g., air gap)
19 .. (2 indent ) Gap with thin film dielectric (e.g., voltage-responsive)
20 .. (2 indent ) With significant housing or casing structure
21 . (1 indent ) Conductive fluid devices
22 . (1 indent ) Fluorescent lamp-starting devices
23 .. (2 indent ) With significant heating means
24 ... (3 indent ) With shunt or short-circuiting means (for resistor)
25 .. (2 indent ) Electric discharge means (e.g., electron-emissive)
26 .. (2 indent ) With significant contact structure or composition
27 ... (3 indent ) Bimetallic element
28 . (1 indent ) Space discharge device (gaps, lightning arrester, etc.)
30 .. (2 indent ) With explosive or combustible material
31 .. (2 indent ) With fusible element (e.g., cutout means)
32 ... (3 indent ) With grounding means
33 ... (3 indent ) With common structural elements (e.g., fuse provides support or element of spark gap structure)
34 .. (2 indent ) Housing, casing, mounting or support means
35 . (1 indent ) Plural diverse similar art-type devices in single switch
36 . (1 indent ) With bimetallic elements (i.e., motion takes place in a plane at right angles to its major axis)
37 .. (2 indent ) With manual or other mechanical contact controlling means
38 ... (3 indent ) Plural elements combined with single mechanical means
39 .... (4 indent ) Independently operative bimetallic elements
40 .... (4 indent ) Individually responsive to diverse conditions or diverse characteristics
41 ... (3 indent ) Multiple contact or plural circuit control means
42 .... (4 indent ) Plural switches
43 .... • (5 indent ) With interlocking means
44 .... (4 indent ) Selectively or alternately actuated
45 .... (4 indent ) Single multipole or polyphase control device
46 .... • (5 indent ) With common mechanical actuating or tripping means
47 .... • (5 indent ) With separate latching or tripping means in each phase
48 .... • . (6 indent ) With common trip-bar means
49 .... • .. (7 indent ) Slidable or reciprocal bar
50 .... • .. (7 indent ) Rotatable
51 ... (3 indent ) Cyclically or periodically actuated
52 ... (3 indent ) With spring or other energy storage device
53 .... (4 indent ) Snap-action
54 .... • (5 indent ) With magnetic flux source (e.g., magnetic armature)
55 .... • (5 indent ) With latching or holding means
56 .... • (5 indent ) With reclosing or reset means
57 .... • (5 indent ) With adjusting or calibration means
58 .... (4 indent ) Compound motion means
59 .... • (5 indent ) Toggle
60 .... • (5 indent ) Floating lever
61 .... (4 indent ) Rotary or oscillatory motion device (e.g., spring motor)
62 .... (4 indent ) Reciprocating or slidable motion device
63 .... • (5 indent ) With lost motion coupling means
64 .... • (5 indent ) With camming or wedging means
65 .... • (5 indent ) With contact guiding or alignment means
66 .... • (5 indent ) With push-button actuating means
67 ... (3 indent ) With contact pressure maintaining or adjusting means
68 ... (3 indent ) With direct contact separating means (e.g., plunger camming means)
69 ... (3 indent ) Independently operative (nontrip-free)
70 ... (3 indent ) Latch or latch-release means
71 .... (4 indent ) Plural or responsive to diverse effects
72 .... (4 indent ) With reclosing or reset means
73 .... • (5 indent ) Automatic
74 .... (4 indent ) Trip-free
75 .... (4 indent ) Bimetallic element unitary with or comprising latch means
76 .... (4 indent ) Performs dual functions (e.g., main contact)
77 .... (4 indent ) With external or auxiliary heater
78 .... (4 indent ) Utilizing plural bimetallic elements
79 ... (3 indent ) With signal or indicating means
80 ... (3 indent ) With mercury or other conductive liquid circuit completion means
81 ... (3 indent ) Retarded or delayed action type
82 ... (3 indent ) With operating range calibration or adjustment means
83 .... (4 indent ) Comprising electric shunt or short-circuiting means
84 .... (4 indent ) Comprising mechanical means
85 .. (2 indent ) Bimetallic element unitary with or directly actuates movable contact means
86 ... (3 indent ) Plural contacts or external circuit connection means
87 .... (4 indent ) Alternately or selectively actuated
88 ... (3 indent ) Retarded or delayed type
89 ... (3 indent ) Snap-action
90 .... (4 indent ) With magnetic armature or holding means
91 .... (4 indent ) With reset means
92 ... (3 indent ) Cyclic or repetitively operative (e.g., flashing)
93 .... (4 indent ) With interval predetermining or adjustment means
94 ... (3 indent ) With operating range, calibration or adjusting means
95 ... (3 indent ) With plural or combined elements
96 .... (4 indent ) Responsive to diverse conditions or of diverse operative characteristics
97 .. (2 indent ) With switch structure protective means
98 .. (2 indent ) With contact operation inhibiting means (e.g., meltable or magnetic)
99 .. (2 indent ) With voltage or ambient temperature compensation means
100 ... (3 indent ) Auxiliary heating means
101 ... (3 indent ) Bimetallic means
102 .. (2 indent ) With external or auxiliary heating means
103 ... (3 indent ) With heater-adjusting, shunting or short-circuiting means
104 ... (3 indent ) Plural heating means
105 ... (3 indent ) With electrical power supply or current control means
106 .... (4 indent ) Inductive means (e.g., transformer)
107 ... (3 indent ) Significant heating element structure or composition
108 .... (4 indent ) Arc or spark gap
109 .. (2 indent ) Contact composition or structure
110 .. (2 indent ) With arc-suppression or blowout means
111 .. (2 indent ) Bimetallic structure or composition of material
112 .. (2 indent ) Housing, casing or support means
113 ... (3 indent ) With external circuit connection means
114 . (1 indent ) Expansible or vaporizable fluid-actuated (e.g., mercury vapor)
115 .. (2 indent ) With manual or other mechanical contact actuating means
116 ... (3 indent ) Cyclically or periodically operative
117 ... (3 indent ) Utilizing diaphragm or bellows means
118 ... (3 indent ) With restoring or resetting means
119 .. (2 indent ) Utilizing capillary tube or bore means
120 .. (2 indent ) With external heating means (external from fluid; may be the container)
121 .. (2 indent ) With housing or casing
122 .. (2 indent ) With contact or electrode structure or material (e.g., carbon)
123 . (1 indent ) With longitudinally expansible solid element (e.g., rod, wire strip, etc.)
124 .. (2 indent ) With voltage or ambient temperature compensation means
125 .. (2 indent ) With electrical shunting or short-circuiting means
126 .. (2 indent ) With manual or other mechanical contact actuating means
127 ... (3 indent ) With delayed action or timing means
128 ... (3 indent ) Latching or tripping means
129 .... (4 indent ) With adjustment or calibration means
130 .... (4 indent ) With reset or reclosing means
131 ... (3 indent ) Snap-action (e.g., bistable)
132 .... (4 indent ) With toggle spring
133 .... (4 indent ) With stop means (e.g., motion limiting)
134 .... (4 indent ) With magnetic biasing or holding means
135 .... (4 indent ) With flexible vane or plate
136 .... • (5 indent ) With preset deformation
137 .. (2 indent ) Contact structure or composition
138 .. (2 indent ) Cyclically or periodically operated (e.g., flasher)
139 .. (2 indent ) With significant expansible element structure or composition of material
140 ... (3 indent ) Wire or other stranded element
141 .. (2 indent ) With external or auxiliary heating means
142 . (1 indent ) Fusible element actuated
143 .. (2 indent ) With manual or other mechanical contact control means
144 ... (3 indent ) Plural fuses combined with single mechanical means
145 ... (3 indent ) Multiple contact or plural circuit control means
146 .... (4 indent ) Multipole or polyphase
147 ... (3 indent ) Snap-action mechanical device
148 ... (3 indent ) Reciprocal or rectilinear sliding motion actuating means (e.g., spring loaded plunger or striker pin)
149 ... (3 indent ) Rotary or oscillatory motion device
150 ... (3 indent ) Latching trip or holding means (actuated by condition by fuse element)
151 .... (4 indent ) Ratchet and pawl
152 .... (4 indent ) Thin film or resoldering (e.g., eutetic alloy)
153 .... (4 indent ) With external or auxiliary heating means
154 .... (4 indent ) Tripping or release means
155 ... (3 indent ) With reclosing or reset means
156 ... (3 indent ) Manually operated shunting, disconnect or load-break device
157 .... (4 indent ) Mechanical fuse link rupturing means
158 .. (2 indent ) Current limiting devices (e.g., high voltage fuses)
159 ... (3 indent ) Comprising significant fuse link or element structure or arrangement
160 .... (4 indent ) With fusible metal overlay (e.g., alloy-forming)
161 .... (4 indent ) Plural elements
162 .... • (5 indent ) With diverse characteristics
163 .. (2 indent ) Delayed action (i.e., time lag)
164 ... (3 indent ) Utilizing plural fusible elements
165 ... (3 indent ) With biased direct circuit opening means
166 ... (3 indent ) With heat absorption, conducting or storage means
167 .. (2 indent ) Convertible (e.g., fused to nonfused)
168 .. (2 indent ) Cutout or disconnect type (an assembly) of a fuse support and fuse holder with or without a fuse link)
169 ... (3 indent ) With kickout means
170 .... (4 indent ) Fusible element controlled
171 ... (3 indent ) With dropout features (i.e., the fuse tube will be separated, or drop away from, at least on the main circuit contacts)
172 .... (4 indent ) Utilizing combined mechanical motions (e.g., sliding with pivotal)
173 .... (4 indent ) Utilizing sliding or reciprocating motions
174 .... (4 indent ) With holding, latch or trip means
175 .... • (5 indent ) Combined latch or trip
176 .... • (5 indent ) Fusible element controlled
177 .... • . (6 indent ) With fuse link extracting means
178 .... • . (6 indent ) Spring biased
179 .... • . (6 indent ) With delayed action
180 ... (3 indent ) Line terminal or contact structure
181 .... (4 indent ) Directly connected by fusible element (e.g., in line-type fuse)
182 .. (2 indent ) With external or auxiliary heating means
183 ... (3 indent ) Resistive heater
184 .... (4 indent ) Directly in series with or completing controlled circuit
185 ... (3 indent ) Comprising or including heat storage or accumulator means
186 .. (2 indent ) Housing, casing or support means
187 ... (3 indent ) With external circuit connection means
188 .... (4 indent ) Plural conductor connector means
189 .... • (5 indent ) Distribution or load center type (e.g., plural outputs)
190 .... (4 indent ) With fuse element tensioning or clamping means
191 .... (4 indent ) Cable or busbar attachment means
192 .... • (5 indent ) Socket or thimble
193 .... • (5 indent ) Line tap, hook or clamp
194 .... (4 indent ) With relatively movable cooperative elements (e.g., pull out)
195 .... • (5 indent ) With spring biasing means
196 .... • (5 indent ) Door or closure controlled
197 .... (4 indent ) Plural diverse (e.g., male and female connectors)
198 .... (4 indent ) Prong or blade (e.g., plug-type housing)
199 ... (3 indent ) With electrical ground, shield or barrier
200 ... (3 indent ) Ceiling block fixture type (e.g., Rosette)
201 ... (3 indent ) With plural interfitting or interlocking sections
202 ... (3 indent ) Bushing or insulator
203 ... (3 indent ) With gaseous venting or expulsion means (from the housing)
204 ... (3 indent ) With oil or other liquid
205 ... (3 indent ) With locking, sealing or guard means
206 ... (3 indent ) With operational condition indicating means
207 ... (3 indent ) With external support or attaching means (e.g., hook)
208 ... (3 indent ) With fuse carrier attachment means
209 .... (4 indent ) Adaptor means
210 .... (4 indent ) Combined with lockout or other circuit closure prevention means
211 .... (4 indent ) With pull out or ejector means (for tube)
212 .... (4 indent ) Door-supported
213 .... (4 indent ) Peculiarly adapted for cartridge fuse
214 .... • (5 indent ) With clamping, latch, or other attachment means
215 .... • . (6 indent ) Spring clip
216 .... (4 indent ) Peculiarly adapted for plug-type fuse carrier (e.g., fuse block)
217 .. (2 indent ) Fuse link extraction or expulsion means
218 ... (3 indent ) Combined with contact structure
219 ... (3 indent ) Spring means
220 ... (3 indent ) Pressure responsive
221 .. (2 indent ) With electrical shunt circuit means (may also be fusible)
222 .. (2 indent ) With switch protective means (for fuse structure)
223 ... (3 indent ) Against shock or recoil
224 ... (3 indent ) Against corona (e.g., shield)
225 .. (2 indent ) With overfusing or tamper prevention means
226 ... (3 indent ) Special adaptor or other selective means
227 .. (2 indent ) Fuse link carrier or holder
228 ... (3 indent ) Cartridge or tube
229 .... (4 indent ) With plural fuse links or elements
230 .... • (5 indent ) Selectively or successively insertable in common circuit
231 .... (4 indent ) With fuse link attaching support or securing means
232 .... • (5 indent ) Soldered or brazed joint
233 .... • (5 indent ) Rigid bar means
234 .... • (5 indent ) Locking or clamping means
235 .... • (5 indent ) Threaded screw or stud
236 .... • (5 indent ) Wedging or camming means
237 .... • (5 indent ) Replaceable or readily interchangeable
238 .... (4 indent ) With fuse link tensioning means
239 .... • (5 indent ) Spring or other energy storage means
240 .... • . (6 indent ) With strain member
241 .... (4 indent ) With indicating or inspection means
242 .... • (5 indent ) Glow lamp
243 .... • (5 indent ) Chemical means
244 .... • (5 indent ) Movable or displaceable element (e.g., plunger or semaphore)
245 .... (4 indent ) With handle or other manipulating means
246 .... (4 indent ) Cartridge or tube structure or material of construction
247 .... • (5 indent ) Plural tubes (e.g., telescoping)
248 .... (4 indent ) Ferrule, cap or other seal means
249 .... (4 indent ) With gas expulsion means
250 .... • (5 indent ) Venting, cooling or deionizing
251 .... (4 indent ) Contact or terminal structure
252 .... • (5 indent ) Attaching or securing means (to the tube or to the fusible element)
253 .... • . (6 indent ) Locking, clamp or wedge means
254 .... • .. (7 indent ) Knife blade contact with slotted disk
256 .... (4 indent ) Plural fusible elements in a single carrier
257 .... • (5 indent ) Selectively or successively insertable in protected circuit
258 .... • . (6 indent ) Selection means
259 .... • .. (7 indent ) Rotatable relatively movable
260 .... (4 indent ) With fuse element attachment or securing means
261 .... • (5 indent ) Resilient biasing or retaining means
262 .... • (5 indent ) Particularly adapted for specific fuse element
263 .... • . (6 indent ) Cartridge or capsule enclosed
264 .... • (5 indent ) Readily replaceable or detachable element
265 .... (4 indent ) With indicating means
266 .... • (5 indent ) Glow lamp or other incandescent means
267 .... • (5 indent ) Plunger or semaphore type
268 .... (4 indent ) Contact or terminal structure
269 .... • (5 indent ) Plural diverse (e.g., male and female)
270 .... (4 indent ) Structure or composition of material
271 .... • (5 indent ) Part of or structurally adapted for use with particular socket means
272 .... • (5 indent ) With venting means
273 .. (2 indent ) With arc suppression or extinguishing means
274 ... (3 indent ) Plural (e.g., auxiliary fuse)
275 .... (4 indent ) With draw-out rod
276 ... (3 indent ) Dielectric filler material or compound (e.g., quartz)
277 .... (4 indent ) Liquid (e.g., hydrocarbon)
278 .... (4 indent ) Dielectric gap or barrier means (e.g., wedging dielectric)
279 ... (3 indent ) Deionizing gas or vapor generating material
280 ... (3 indent ) Cooling, condensing or absorbing means
281 ... (3 indent ) Blowout means (e.g., gaseous)
282 ... (3 indent ) Arcing chamber or passage structure
283 .. (2 indent ) Plural independent fuses
284 ... (3 indent ) Selectively or sequentially inserted in same protected circuit
285 .... (4 indent ) Automatic selective means (e.g., repeater type)
286 .... • (5 indent ) With delayed action selective means
287 .... • . (6 indent ) Hydraulic or pneumatic
288 .... • (5 indent ) Transfer or interlock means
289 .... (4 indent ) Rotary selector means
290 .. (2 indent ) Fusible link or element structure or material
291 ... (3 indent ) With strain-relief means
292 ... (3 indent ) Plural series-connected conductive elements forming a single link
293 ... (3 indent ) Plural parallel fusible elements
294 ... (3 indent ) Continuous strand adapted for successive insertion in protected circuit
295 ... (3 indent ) With particular geometrical shape or configuration
296 ... (3 indent ) Composite (e.g., with overlay)
297 ... (3 indent ) With nonconductive core (e.g., printed circuit)
298 THERMALLY ACTUATED SWITCHES
299 . (1 indent ) Plural diverse actuating means in single switch
300 . (1 indent ) Responsive to plural external conditions (e.g., temperature and humidity)
301 . (1 indent ) With mechanical timing means (e.g., clockwork)
302 .. (2 indent ) Periodic or cyclically operative
303 ... (3 indent ) With predetermined operative cycle adjusting means
304 .. (2 indent ) With predetermined operative temperature range
305 ... (3 indent ) Utilizing cam or eccentric
306 . (1 indent ) Expansible or vaporizable fluid actuated
307 .. (2 indent ) Plural expansible elements with single switch
308 ... (3 indent ) Individually responsive to diverse conditions or of diverse characteristics
309 .. (2 indent ) Multiple contacts or external circuit completion means
310 ... (3 indent ) Plural independent switches
311 ... (3 indent ) Selective, sequentially or alternately actuated
312 .. (2 indent ) With manual or other mechanical contact control means
313 ... (3 indent ) Combined or compound motion device
314 ... (3 indent ) Reciprocating or sliding motion
315 .... (4 indent ) Piston or plunger
316 ... (3 indent ) Rotary or oscillatory motion device
317 ... (3 indent ) With spring or other energy storage means
318 .... (4 indent ) Snap-action
319 .... • (5 indent ) With adjusting, calibrating or compensating means
320 .. (2 indent ) With diaphragm or bellows structure
321 ... (3 indent ) Combined with capillary tube or bore
322 .. (2 indent ) With Bourdon tube
323 .. (2 indent ) With operating range calibration or adjustment means
324 .. (2 indent ) With auxiliary heater
325 .. (2 indent ) With latching, locking or holding means
326 .. (2 indent ) Fluid or fluid pressure generating means
327 .. (2 indent ) Housing, casing or support means
328 ... (3 indent ) With pressure relief (e.g., venting)
329 .. (2 indent ) Contact structure or composition of material
330 ... (3 indent ) With relative position adjustment means
331 ... (3 indent ) Comprising conductive liquid (e.g., mercury)
332 .. (2 indent ) With signaling, alarm or visual indicator means
333 . (1 indent ) With bimetallic element
334 .. (2 indent ) With manual or other mechanical contact control means
335 ... (3 indent ) Plural elements combined with single mechanical means
336 .... (4 indent ) Individually responsive to diverse conditions or of diverse operating characteristics
337 ... (3 indent ) Multiple contact or plural circuit control means
338 .... (4 indent ) Plural separate switches
339 .... • (5 indent ) With interlocking
340 .... (4 indent ) With contacts selectively, alternately or sequentially actuated
341 ... (3 indent ) With time-delay means
342 ... (3 indent ) With spring or other energy storage means
343 .... (4 indent ) Snap-action
344 .... • (5 indent ) With magnetic flux source (e.g., magnetic armature)
345 .... • (5 indent ) With toggle linkage
346 .... • (5 indent ) With frictional coupling or lost motion means
347 .... • (5 indent ) With adjusting or calibration means
348 .... • (5 indent ) With reset or reclosing means
349 ... (3 indent ) With contact biasing, pressure control or adjusting means
350 ... (3 indent ) Compound motion means
351 ... (3 indent ) Rotary or oscillatory motion means
352 .... (4 indent ) With frictional clutch drive means
353 .... (4 indent ) Including cam and follower
354 ... (3 indent ) Reciprocating or slidable motion means
355 ... (3 indent ) Independently operative
356 ... (3 indent ) Latch or latch-release means
357 .... (4 indent ) Adjustable
358 .... (4 indent ) With reclosing or reset means
359 .... (4 indent ) With bimetallic element comprising or unitary with latch
360 .. (2 indent ) With operating range calibration or adjustment means
361 ... (3 indent ) Utilizing cam or roller
362 .. (2 indent ) Bimetallic element unitary with or directly actuates contacts
363 ... (3 indent ) Multiple contacts or external circuit control means
364 .... (4 indent ) Alternately or selectively actuated
365 ... (3 indent ) Snap-action
366 .... (4 indent ) With magnetic flux source
367 .... (4 indent ) With reset means
368 .... (4 indent ) With adjustment or calibration means
369 ... (3 indent ) Cyclically or repetitively operative
370 ... (3 indent ) With plural bimetallic elements
371 .... (4 indent ) Of diverse operating characteristics or responsive to diverse conditions
372 ... (3 indent ) Element attachment or mounting means
373 .. (2 indent ) Contact structure or composition of material (e.g., mercury)
374 ... (3 indent ) With position adjusting means
375 .... (4 indent ) Leaf spring with direct thrust element
376 .. (2 indent ) With signal or indicating means
377 .. (2 indent ) With auxiliary heating means
378 .. (2 indent ) With compensation means (e.g., ambient temperature)
379 .. (2 indent ) Bimetallic element structure or composition of material
380 .. (2 indent ) Housing, casing or support structure
381 ... (3 indent ) With significant external circuit connection means
382 . (1 indent ) With longitudinally expansible solid element
383 .. (2 indent ) With plural contacts or external circuit completion means
384 .. (2 indent ) With manual or other mechanical contact control means
385 ... (3 indent ) Latching or tripping means
386 ... (3 indent ) Comprising mechanical advantage or force multiplying means
387 ... (3 indent ) Comprising frictional clutch or lost motion means
388 ... (3 indent ) With spring or other energy storage means
389 .... (4 indent ) Comprising resilient leaf spring
390 .... (4 indent ) Snap-action
391 .... • (5 indent ) With flexible vane or plate
392 .. (2 indent ) With operating range calibration or adjusting means
393 .. (2 indent ) Expansible solid structure or composition of material
394 ... (3 indent ) Rod, tube or cylinder
395 ... (3 indent ) Wire or stranded material
396 ... (3 indent ) Diaphragm, strip or ribbon
397 .. (2 indent ) Plural deformable elements in single switch
398 .. (2 indent ) Housing, casing or support means
399 .. (2 indent ) Contact or terminal structural or composition of material
400 ... (3 indent ) With position adjustment means
401 . (1 indent ) With fusible, combustible or explosive material
402 .. (2 indent ) With manual, gravity-actuated or other mechanical contact control means
403 ... (3 indent ) Automatic cutout or disconnect type
404 .... (4 indent ) With fusible element directly connecting contacts
405 .... (4 indent ) With fusible element opening the circuit (no mechanical contacts)
406 ... (3 indent ) Multiple contacts or plural circuit control means
407 ... (3 indent ) Utilizing spring or other energy
408 .... (4 indent ) Reciprocating or slidable motion device
409 .... • (5 indent ) Plunger or piston
410 .... (4 indent ) Rotatable
411 ... (3 indent ) Latch, trip or holding means
412 .. (2 indent ) Plural independent fuse elements with single circuit completion means
413 .. (2 indent ) Contact structure or composition of material
414 .. (2 indent ) Housing, casing or support means
415 ... (3 indent ) Flexible or resilient
416 .. (2 indent ) Fusible, link or element structure or composition of material
FOR000 CLASS-RELATED FOREIGN DOCUMENTS
Note: Some content
linked to on this page may require a plug-in for Adobe
Acrobat Reader .
This file produced by USPTO - SIRA -
Office of Patent Automation - ReferenceTools Project.
Questions or comments relating to this file should be
directed to Patent
Automation Feedback .