 Class   218HIGH-VOLTAGE SWITCHES WITH ARC PREVENTING OR EXTINGUISHING DEVICES
  Click here to view a PDF version of this file
 This Class 218 is considered to be an integral part of Class 200 (see the Class 200 schedule for the position of this Class in schedule hierarchy). This Class retains all pertinent definitions and class lines of Class 200.
 
  1           ARC PREVENTING OR EXTINGUISHING DEVICES
  2           . (1 indent ) Multiple break
  3           .. (2 indent ) Hybrid-type
  4           .. (2 indent ) Series connected break
  5           .. (2 indent ) Simultaneous break
  6           .. (2 indent ) Sequential break
  7           .. (2 indent ) Operating mechanism structure or arrangement
  8           . (1 indent ) Auxiliary shunt
  9           .. (2 indent ) Polyphase
  10           .. (2 indent ) Vacuum switch
  11           .. (2 indent ) Tubular shaped
  12           .. (2 indent ) Disconnect switch
  13           .. (2 indent ) Gas type
  14           .. (2 indent ) Operating mechanism structure or arrangement
  15           .. (2 indent ) Arc chute assembly
  16           .. (2 indent ) Contact structure
  17           ... (3 indent ) Movable contact assembly
  18           .... (4 indent ) Arcing contact
  19           .... (4 indent ) Movable contact assembly reciprocates
  20           .... (4 indent ) Movable contact assembly pivots
  21           .... (5 indent ) Arcing contact pivots relative to movable main contact assembly
  22           . (1 indent ) Magnetic blowout
  23           .. (2 indent ) Permanent magnet
  24           ... (3 indent ) Magnetic yoke structure
  25           ... (3 indent ) Located outside switch housing
  26           ... (3 indent ) Located inside switch housing
  27           ... (3 indent ) Connected to contact
  28           ... (3 indent ) Plural coils
  29           .. (2 indent ) Arc Spinner
  30           .. (2 indent ) Contact structure
  31           ... (3 indent ) Bridging contacts
  32           ... (3 indent ) Pivot
  33           ... (3 indent ) Reverse looped or flexible stationary contact
  34           .. (2 indent ) Arc chute
  35           ... (3 indent ) With vent means
  36           ... (3 indent ) Arc runner (e.g., arc horn)
  37           ... (3 indent ) Insulated conductor structure
  38           .... (4 indent ) Arc splitting means
  39           .... (4 indent ) Skew, parallel, or vertical position
  40           .. (2 indent ) Arc runner (e.g., arc horn)
  41           .. (2 indent ) Barrier
  42           .. (2 indent ) Within vacuum
  43           . (1 indent ) Air-current blowout
  44           .. (2 indent ) Polyphase
  45           .. (2 indent ) Disconnect switch
  46           .. (2 indent ) Arcing chamber
  47           ... (3 indent ) Plural chambers
  48           .. (2 indent ) Contact structure
  49           ... (3 indent ) Fixed
  50           ... (3 indent ) Movable
  51           .. (2 indent ) With gas flow means
  52           ... (3 indent ) Exhaust port
  53           .. (2 indent ) With nozzle
  54           ... (3 indent ) With throat region
  55           .. (2 indent ) Grounding switch
  56           .. (2 indent ) Self extinguishing
  57           .. (2 indent ) Puffer piston
  58           ... (3 indent ) Polyphase
  59           ... (3 indent ) With gas blast means
  60           .... (4 indent ) Piston structure
  61           .... (4 indent ) Compressing cylinder structure
  62           .... (5 indent ) With nozzle
  63           ... (3 indent ) With nozzle
  64           .... (4 indent ) With throat region
  65           ... (3 indent ) Contact structure
  66           ... (3 indent ) Valve (e.g., blast valve or pressure relief valve)
  67           ... (3 indent ) Disconnect switch
  68           .. (2 indent ) Sealed chamber
  69           ... (3 indent ) Plural switch connected in series
  70           .... (4 indent ) Hybrid-type
  71           ... (3 indent ) Polyphase
  72           ... (3 indent ) With nozzle
  73           .... (4 indent ) With throat region
  74           ... (3 indent ) Contact structure
  75           ... (3 indent ) Busbar
  76           ... (3 indent ) Arcing chamber
  77           ... (3 indent ) Shielding
  78           ... (3 indent ) Operating mechanism structure or arrangement
  79           ... (3 indent ) Grounding switch
  80           ... (3 indent ) Disconnect switch
  81           .. (2 indent ) Arc chute
  82           .. (2 indent ) Identical units back-to-back
  83           .. (2 indent ) Recirculating systems
  84           .. (2 indent ) Operating mechanism structure or arrangement
  85           .. (2 indent ) Arc extinguishing medium
  86           .. (2 indent ) Low pressure cut-off valve means
  87           .. (2 indent ) Magnetic synchronous contacts
  88           .. (2 indent ) Control of blast valve and contacts
  89           . (1 indent ) Interposed non-conductor
  90           .. (2 indent ) Gas-evolving chamber
  91           .. (2 indent ) Liquid
  92           ... (3 indent ) Operating mechanism structure or arrangement
  93           .... (4 indent ) Piston
  94           .... (4 indent ) Delay means (e.g., dashpot)
  95           .... (4 indent ) Chemical explosive primer
  96           .... (4 indent ) With oil flow feature
  97           ... (3 indent ) Housing or tank structure
  98           .... (4 indent ) With raising and lowering means
  99           .... (4 indent ) With venting means
  100           ... (3 indent ) Disconnect switch
  101           ... (3 indent ) Polyphase
  102           ... (3 indent ) With resistor
  103           ... (3 indent ) Arcing chamber
  104           .... (4 indent ) Including magnet or coil
  105           .... (4 indent ) Grid or baffle stack
  106           .... (4 indent ) With venting means
  107           ... (3 indent ) Contact structure
  108           .... (4 indent ) Movable
  109           ... (3 indent ) Valve (e.g., spring biased valve plate)
  110           ... (3 indent ) Bridging contacts
  111           ... (3 indent ) Explosion pot
  112           ... (3 indent ) Oil poor breaker
  113           ... (3 indent ) Rotary contact
  114           ... (3 indent ) Pressure generating arc control means
  115           .... (4 indent ) Plural series connected
  116           ... (3 indent ) Puffer-piston
  117           .. (2 indent ) Solid
  118           . (1 indent ) Vacuum
  119           .. (2 indent ) Polyphase
  120           ... (3 indent ) Operating mechanism structure or arrangement
  121           .. (2 indent ) Single-pole
  122           ... (3 indent ) Pressure monitoring means
  123           ... (3 indent ) Contact structure
  124           .... (4 indent ) Movable
  125           .... (4 indent ) Fixed
  126           .... (4 indent ) Auxiliary
  127           .... (4 indent ) Significant shape
  128           .... (5 indent ) Slotted or grooved
  129           .... (5 indent ) Coil
  130           .... (4 indent ) Specific material
  131           .... (5 indent ) Getter
  132           .... (5 indent ) Alloy
  133           .... (5 indent ) Beryllium
  134           ... (3 indent ) Housing structure
  135           .... (4 indent ) Bellows
  136           .... (4 indent ) Shielding
  137           .... (5 indent ) With support
  138           .... (4 indent ) Potted or encapsulated
  139           .. (2 indent ) Housing structure
  140           .. (2 indent ) Operating mechanism structure or arrangement
  141           .. (2 indent ) With magnetic coil
  142           ... (3 indent ) Located inside housing
  143           . (1 indent ) Resistance inserting
  144           .. (2 indent ) With capacitor
  145           . (1 indent ) With capacitor
  146           . (1 indent ) Contact structure
  147           .. (2 indent ) Arc shielding means
  148           . (1 indent ) Arc runner (e.g., arc horn)
  149           . (1 indent ) Arc chute assembly
  150           .. (2 indent ) Material
  151           .. (2 indent ) Metal plates structure
  152           . (1 indent ) Polyphase
  153           .. (2 indent ) Operating mechanism structure or arrangement
  154           . (1 indent ) Operating mechanism structure or arrangement
  155           . (1 indent ) Housing structure
  156           .. (2 indent ) Arcing chamber
  157           ... (3 indent ) With venting means
  158           ... (3 indent ) Arc extinguishing material
 
 FOREIGN ART COLLECTIONS
 
  FOR000           CLASS-RELATED FOREIGN DOCUMENTS


   Note: Some content linked to on this page may require a plug-in for Adobe Acrobat Reader.

This file produced by USPTO - SIRA - Office of Patent Automation - ReferenceTools Project. Questions or comments relating to this file should be directed to Patent Automation Feedback.

Click to skip end of page links


Intranet Home | Index | Resources | Contacts | Internet | Search | Firewall | Web Services

This data is current as of June/2006