![]() | G01N 31/00 | Investigating or analysing non-biological materials by the use of the chemical methods specified in the subgroup (testing the effectiveness or completeness of sterilisation procedures without using enzymes or microorganisms A61L 2/28; measuring or testing processes involving enzymes or micro-organisms C12Q 1/00); Apparatus specially adapted for such methods |
G01N 31/002 | . | { Determining nitrogen by transformation into ammonia, e.g. KJELDAHL method} |
![]() | G01N 31/005 | . |
G01N 31/007 | . . | NOTE -
|
G01N 31/02 | . | using precipitation { measuring deposition or liberation of materials from an electrolyte G01N 27/42} |
G01N 31/10 | . | using catalysis |
G01N 31/12 | . | using combustion (G01N 25/20 takes precedence) |
![]() | G01N 31/16 | . | using titration |
![]() | G01N 31/162 | . . | { Determining the equivalent point by means of a discontinuity} |
G01N 31/166 | . . | { Continuous titration of flowing liquids} |
G01N 31/168 | . . | { Determining water content by using Karl Fischer reagent} |
G01N 31/18 | . . | Burettes specially adapted for titration (burettes in general B01L 3/02) |
G01N 31/20 | . | using micro-analysis, e.g. drop reaction |
![]() | G01N 31/22 | . | using chemical indicators (G01N 31/02 takes precedence) |
G01N 31/221 | . . | { for investigating pH value} |
G01N 31/222 | . . | { for investigating moisture content} |
![]() | G01N 31/223 | . . | { for investigating presence of specific gases or aerosols (G01N 31/221, G01N 31/222 take precedence; actuation of fire alarm by presence of smoke or gases G08B 17/10)} |
G01N 31/224 | . . . | { for investigating presence of dangerous gases} |
G01N 31/225 | . . . | { for oxygen, e.g. including dissolved oxygen} |
G01N 31/226 | . . | { for investigating the degree of sterilisation} |
G01N 31/227 | . . | { for nitrates or nitrites} |
G01N 31/228 | . . | { for peroxides} |
G01N 31/229 | . . | { for investigating time/temperature history} |
![]() | G01N 33/00 | Investigating or analysing materials by specific methods not covered by the preceding groups |
G01N 33/0001 | . | { by organoleptic means} |
![]() | G01N 33/0004 | . | { Gaseous mixtures, e.g. polluted air (gaseous biological material G01N 33/497; exhaust gas of internal combustion engines G01M15/00D4)} |
![]() | G01N 33/0006 | . . | { Calibrating gas analysers} |
![]() | G01N 33/0009 | . . | { General constructional details of gas analysers, e.g. portable test equipment (G01N 1/22 takes precedence)} |
![]() | G01N 33/0011 | . . . |
G01N 33/0013 | . . . . |
G01N 33/0014 | . . . . |
G01N 33/0016 | . . . . | { by regulating a physical variable, e.g. pressure, temperature} |
G01N 33/0018 | . . . . | { by diluting a gas} |
G01N 33/0021 | . . . . | { involving the use of a carrier gas for transport to the sensor} |
![]() | G01N 33/0022 | . . . | { using a number of analysing channels} |
G01N 33/0024 | . . . . | { a chemical reaction taking place or a gas being eliminated in one or more channels} |
G01N 33/0026 | . . . |
![]() | G01N 33/0027 | . . . | { concerning the detector} |
G01N 33/0029 | . . . . | { cleaning} |
![]() | G01N 33/0031 | . . . . | { comprising two or more sensors, e.g. a sensor array (electrochemical electrode arrays G01N 27/27)} |
G01N 33/0032 | . . . . . | { using two or more different physical functioning modes} |
G01N 33/0034 | . . . . . | { comprising neural networks or related mathematical techniques} |
![]() | G01N 33/0036 | . . . . | { Specially adapted to detect a particular component (all the other sub-groups of G01N 33/0004 take precedence)} |
G01N 33/0037 | . . . . . | { for NOx} |
G01N 33/0039 | . . . . . | { for O3} |
G01N 33/004 | . . . . . | { for CO, CO2} |
G01N 33/0042 | . . . . . | { for SO2, SO3} |
G01N 33/0044 | . . . . . | { for H2S, sulfides} |
G01N 33/0045 | . . . . . | { for Hg} |
![]() | G01N 33/0047 | . . . . . | { for organic compounds} |
G01N 33/005 | . . . . . | { for H2} |
G01N 33/0052 | . . . . . | { for gaseous halogens} |
G01N 33/0054 | . . . . . | { for ammonia} |
G01N 33/0055 | . . . . . | { for radionuclides} |
G01N 33/0057 | . . . . . |
![]() | G01N 33/0059 | . . . . . | { avoiding interference of a gas with the gas to be measured} |
![]() | G01N 33/0062 | . . . | { concerning the measuring method, e.g. intermittent, or the display, e.g. digital} |
![]() | G01N 33/0063 | . . . . | { using a threshold to release an alarm or displaying means (alarm arrangements G08B, e.g. fire alarm actuated by the presence of smoke or gases G08B 17/10, for other abnormal conditions G08B 21/00)} |
G01N 33/0067 | . . . . | { by measuring the rate of variation of the concentration} |
G01N 33/007 | . . . |
![]() | G01N 33/0073 | . . . | { Control unit therefor} |
G01N 33/0098 | . |
![]() | G01N 33/02 | . | food |
G01N 33/025 | . . | { Fruits or vegetables} |
G01N 33/03 | . . | edible oils or edible fats |
![]() | G01N 33/04 | . . | dairy products |
![]() | G01N 33/08 | . . | eggs, e.g. by candling |
G01N 33/10 | . . | starch-containing substances, e.g. dough |
G01N 33/12 | . . | meat; fish |
![]() | G01N 33/14 | . . | beverages |
G01N 33/15 | . | Medicinal preparations; { Physical properties thereof, e.g. dissolubility (drug screening with animal cells G01N 33/5008, drug screening with microorganisms C12Q 1/025)} |
![]() | G01N 33/18 | . | Water { (treatment of water C02F)} |
G01N 33/1806 | . . | { biological or chemical oxygen demand (BOD or COD)} |
G01N 33/1813 | . . | { specific cations in water, e.g. heavy metals (electrochemical analysis 27/26; detection of ions by colorimetry G01N 31/22)} |
G01N 33/182 | . . | { specific anions in water (electrochemical analysis G01N 27/26; detection of ions by colorimetry G01N 31/22)} |
![]() | G01N 33/1826 | . . | { organic contamination in water} |
G01N 33/1853 | . . | { hardness of water} |
![]() | G01N 33/186 | . . | { using one or more living organisms, e.g. a fish} |
G01N 33/188 | . . | { Determining the state of nitrification (biological treatment of water by aerobic or anaerobic processes for denitrification of water C02F3/30A)} |
G01N 33/1886 | . . | { using probes, e.g. submersible probes, buoys} |
G01N 33/1893 | . . | { using flow cells} |
![]() | G01N 33/20 | . | metals |
G01N 33/203 | . . | { for the presence of a volatilizable e.g. gaseous component} |
G01N 33/206 | . . | { in molten state, e.g. after local fusion} |
![]() | G01N 33/22 | . |
G01N 33/222 | . . | { Solid fuels, e.g. coal} |
G01N 33/225 | . . | { Gaseous fuels, e.g. natural gas} |
G01N 33/227 | . . |
![]() | G01N 33/24 | . | earth materials (G01N 33/42 takes precedence; { testing the nature of borehole walls, formation testing E21B 49/00; investigation of foundation soil in situ E02D 1/00; geophysics, e.g. prospecting G01V} ) |
![]() | G01N 33/26 | . | oils; viscous liquids; paints; inks (G01N 33/22 takes precedence) |
![]() | G01N 33/28 | . . | Oils, { i.e. hydrocarbon liquids (gaseous fuels G01N 33/225)} (edible oils or edible fats G01N 33/03) |
G01N 33/2805 | . . . | { investigating the resistance to heat or oxidation (to the weather, to corrosion, or to light G01N 17/00)} |
G01N 33/2811 | . . . | { by measuring cloud point or pour point of oils} |
G01N 33/2817 | . . . |
G01N 33/2823 | . . . | { raw oil, drilling fluid or polyphasic mixtures (hydrocarbon content of earth materials G01N 33/241; prospecting G01V; drilling per se E21B)} |
G01N 33/2829 | . . . | { mixtures of fuels, e.g. determining the RON-number} |
![]() | G01N 33/2835 | . . . | { specific substances contained in the oil or fuel} |
G01N 33/2841 | . . . . | { gas in oil, e.g. hydrogen in insulating oil} |
G01N 33/2847 | . . . . |
G01N 33/2852 | . . . . | { alcohol/fuel mixtures} |
G01N 33/2858 | . . . . | { metal particles} |
G01N 33/2864 | . . . . | { lead content} |
G01N 33/287 | . . . . | { Sulfur content} |
G01N 33/2876 | . . . . | { Total acid number} |
G01N 33/2882 | . . . . |
G01N 33/2888 | . . . |
G01N 33/2894 | . . . | { for metal working or machining} |
G01N 33/30 | . . . | for lubricating properties |
G01N 33/32 | . . |
![]() | G01N 33/34 | . | paper |
![]() | G01N 33/36 | . | textiles |
![]() | G01N 33/38 | . | concrete; ceramics; glass; bricks |
G01N 33/381 | . . | { precious stones; pearls} |
G01N 33/383 | . . | { Concrete, cement} |
G01N 33/385 | . . | { Crystals} |
G01N 33/386 | . . | { Glass} |
G01N 33/388 | . . | { Ceramics} |
G01N 33/40 | . | grinding-materials |
G01N 33/42 | . | road-making materials (G01N 33/38 takes precedence) |
![]() | G01N 33/44 | . | resins; rubber; leather |
G01N 33/46 | . | wood |
![]() | G01N 33/48 | . | biological material, e.g. blood, urine (G01N 33/02 to G01N 33/14, G01N 33/26, G01N 33/44, G01N 33/46 take precedence; determining the germinating capacity of seeds A01C 1/02); Haemocytometers (counting blood corpuscules distributed over a surface by scanning the surface G06M 11/02) |
![]() | G01N 33/483 | . . | Physical analysis of biological material |
![]() | G01N 33/4833 | . . . | { of solid biological material, e.g. tissue samples, cell cultures (tissue in vivo A61B5; cell suspensions G01N 33/48735)} |
![]() | G01N 33/487 | . . . | of liquid biological material |
![]() | G01N 33/48707 | . . . . |
G01N 33/48714 | . . . . . | { for determining substances foreign to the organism, e.g. drugs or heavy metals (drugs by chemical analysis G01N 33/94)} |
G01N 33/48721 | . . . . . | { Investigating individual macromolecules, e.g. by translocation through nanopores (Coulter counters in general G01N 15/12; fabrication methods for nano-scale apertures B81B 1/00; sequencing of nucleic acids C12Q 1/68
)} |
G01N 33/48728 | . . . . . | { Investigating individual cells, e.g. by patch clamp, voltage clamp (investigating individual particles in general G01N 15/10)} |
G01N 33/48735 | . . . . . | { Investigating suspensions of cells, e.g. measuring microbe concentration (by chemical means C12Q 1/04; colony counters C12M 1/34; concentration of particle suspensions in general G01N 15/06)} |
G01N 33/48742 | . . . . |
![]() | G01N 33/4875 | . . . . | { Details of handling test elements, e.g. dispensing or storage, not specific to a particular test method (test-elements per se B01L, automatic analysers G01N 35/00, in-vivo analysis on the human body for medical diagnosis A61B)} |
G01N 33/48757 | . . . . . | { Test elements dispensed from a stack} |
G01N 33/48764 | . . . . . | { Test tape taken off a spool} |
G01N 33/48771 | . . . . . | { Coding of information, e.g. calibration data, lot number} |
G01N 33/48778 | . . . . . | { Containers specially adapted therefor, e.g. for dry storage} |
G01N 33/48792 | . . . . . | { Data management, e.g. communication with processing unit (for in vivo diagnostics A61B5/64; medical informatics G06F19/00M; transmission systems for measured values G08C)} |
![]() | G01N 33/49 | . . . . | Blood { (taking blood samples A61B 5/15; chemical methods for determining blood cell populations G01N 33/5094; chemical analysis of blood groups or blood types G01N 33/80)} |
G01N 33/4905 | . . . . . |
G01N 33/491 | . . . . . |
G01N 33/4915 | . . . . . |
G01N 33/492 | . . . . . | { Determining multiple analytes} |
G01N 33/4925 | . . . . . |
G01N 33/493 | . . . . | urine |
![]() | G01N 33/497 | . . . |
![]() | G01N 33/50 | . . | Chemical analysis of biological material, e.g. blood, urine; Testing involving biospecific ligand binding methods; Immunological testing (measuring or testing processes involving enzymes or micro-organisms, compositions or test papers therefor; processes for forming such compositions, condition responsive control in microbiological or enzymological processes C12Q) NOTE -
|
G01N 33/5002 | . . . | { Partitioning blood components} |
![]() | G01N 33/5005 | . . . | { involving human or animal cells (immunoassay G01N 33/569H; immunoassays of protozoa G01N 33/569B; protozoa in screening assays C12Q 1/02B)} |
![]() | G01N 33/5008 | . . . . | { for testing or evaluating the effect of chemical or biological compounds, e.g. drugs, cosmetics} |
G01N 33/5011 | . . . . . | { for testing antineoplastic activity} |
![]() | G01N 33/5014 | . . . . . | { for testing toxicity} |
![]() | G01N 33/502 | . . . . . | { for testing non-proliferative effects} |
G01N 33/5023 | . . . . . . | { on expression patterns} |
G01N 33/5026 | . . . . . . | { on cell morphology} |
G01N 33/5029 | . . . . . . | { on cell motility} |
G01N 33/5032 | . . . . . . | { on intercellular interactions} |
G01N 33/5035 | . . . . . . | { on sub-cellular localization} |
G01N 33/5038 | . . . . . . | { involving detection of metabolites per se} |
G01N 33/5041 | . . . . . . | { involving analysis of members of signalling pathways} |
![]() | G01N 33/5044 | . . . . . | { involving specific cell types} |
![]() | G01N 33/5047 | . . . . . . | { Cells of the immune system} |
G01N 33/505 | . . . . . . . | { involving T-cells} |
G01N 33/5052 | . . . . . . . | { involving B-cells} |
G01N 33/5055 | . . . . . . . | { involving macrophages} |
G01N 33/5058 | . . . . . . | { Neurological cells} |
G01N 33/5061 | . . . . . . | { Muscle cells} |
G01N 33/5064 | . . . . . . | { Endothelial cells} |
G01N 33/5067 | . . . . . . | { Liver cells} |
G01N 33/507 | . . . . . . | { Pancreatic cells} |
G01N 33/5073 | . . . . . . | { Stem cells} |
![]() | G01N 33/5076 | . . . . . | { involving cell organelles, e.g. Golgi complex, endoplasmic reticulum} |
![]() | G01N 33/5082 | . . . . . | { Supracellular entities, e.g. tissue, organisms} |
G01N 33/5091 | . . . . | { for testing the pathological state of an organism} |
G01N 33/5094 | . . . . |
G01N 33/5097 | . . . | { involving plant cells (immunoassays of plant cells G01N 33/56961; unicellular algae, photoplankton and photosynthetic bacteria in screening assays C12Q 1/025)} |
![]() | G01N 33/52 | . . . | Use of compounds or compositions for colorimetric, spectrophotometric or fluorometric investigation, e.g. use of reagent paper { and including single- and multilayer analytical elements (immunological elements G01N 33/54386; involving labelled immunochemicals G01N 33/58; for haemoglobin or occult blood G01N 33/72)} |
![]() | G01N 33/521 | . . . . | { Single-layer analytical elements} |
![]() | G01N 33/525 | . . . . | { Multi-layer analytical elements} |
G01N 33/528 | . . . . | { Atypical element structures, e.g. gloves, rods, tampons, toilet paper} |
![]() | G01N 33/53 | . . . | Immunoassay; Biospecific binding assay (preparations containing antigens or antibodies for therapeutic purposes A61K 39/00; haptens in general, see the relevant places in class C07; proteins in general C07K) |
![]() | G01N 33/5302 | . . . . | { Apparatus specially adapted for immunological test procedures} |
G01N 33/5306 | . . . . | { Improving reaction conditions, e.g. reduction of non-specific binding, promotion of specific binding} |
G01N 33/5308 | . . . . | { for analytes not provided for elsewhere, e.g. nucleic acids, uric acid, worms, mites} |
![]() | G01N 33/531 | . . . . | Production of immunochemical test materials |
![]() | G01N 33/536 | . . . . | with immune complex formed in liquid phase |
![]() | G01N 33/537 | . . . . . | with separation of immune complex from unbound antigen or antibody |
G01N 33/5375 | . . . . . . | { by changing the physical or chemical properties of the medium or immunochemicals, e.g. temperature, density, pH, partitioning} |
G01N 33/538 | . . . . . . | by sorbent column, particles or resin strip { i.e. sorbent materials} |
![]() | G01N 33/539 | . . . . . . | involving precipitating reagent { e.g. ammonium sulfate} |
G01N 33/542 | . . . . . | with steric inhibition or signal modification, e.g. fluorescent quenching |
![]() | G01N 33/543 | . . . . | with an insoluble carrier for immobilising immunochemicals |
G01N 33/54306 | . . . . . | { Solid-phase reaction mechanisms} |
![]() | G01N 33/54313 | . . . . . | { the carrier being characterised by its particulate form} |
G01N 33/5432 | . . . . . . | { Liposomes or microcapsules} |
![]() | G01N 33/54326 | . . . . . . | { Magnetic particles} |
G01N 33/5434 | . . . . . . . | { using magnetic particle immunoreagent carriers which constitute new materials per se} |
G01N 33/54346 | . . . . . . | { Nanoparticles} |
G01N 33/54353 | . . . . . |
G01N 33/5436 | . . . . . | { with ligand physically entrapped within the solid phase (liposomes G01N 33/5432; immunological test elements G01N 33/54386)} |
![]() | G01N 33/54366 | . . . . . | { Apparatus specially adapted for solid-phase testing} |
![]() | G01N 33/54373 | . . . . . . | { involving physiochemical end-point determination, e.g. wave-guides, FETS, gratings} |
G01N 33/54386 | . . . . . . | { Analytical elements} |
G01N 33/54393 | . . . . . | { Improving reaction conditions or stability, e.g. by coating or irradiation of surface, by reduction of non-specific binding, by promotion of specific binding} |
![]() | G01N 33/544 | . . . . . | the carrier being organic |
![]() | G01N 33/545 | . . . . . . | Synthetic resin |
G01N 33/548 | . . . . . . | Carbohydrates, e.g. dextran |
G01N 33/549 | . . . . . . |
![]() | G01N 33/551 | . . . . . | the carrier being inorganic |
![]() | G01N 33/554 | . . . . . | the carrier being a biological cell or cell fragment, e.g. bacteria, yeast cells |
G01N 33/557 | . . . . | using kinetic measurement, i.e. time rate of progress of an antigen-antibody interaction |
![]() | G01N 33/558 | . . . . | using diffusion or migration of antigen or antibody |
G01N 33/559 | . . . . . | through a gel, e.g. Ouchterlony technique |
G01N 33/561 | . . . . . | Immunoelectrophoresis |
G01N 33/563 | . . . . |
![]() | G01N 33/566 | . . . . | using specific carrier or receptor proteins as ligand binding reagents { where possible specific carrier or receptor proteins are classified with their target compounds} |
![]() | G01N 33/569 | . . . . | for micro-organisms, e.g. protozoa, bacteria, viruses |
G01N 33/56905 | . . . . . | { Protozoa} |
![]() | G01N 33/56911 | . . . . . | { Bacteria} |
G01N 33/56916 | . . . . . . | { Enterobacteria; e.g. shigella, salmonella, klebsiella, serratia} |
G01N 33/56922 | . . . . . . | { Campylobacter} |
G01N 33/56927 | . . . . . . | { Chlamydia} |
G01N 33/56933 | . . . . . . | { Mycoplasma} |
G01N 33/56938 | . . . . . . | { Staphylococcus} |
G01N 33/56944 | . . . . . . | { Streptococcus} |
G01N 33/5695 | . . . . . . | { Mycobacteria} |
G01N 33/56955 | . . . . . . | { involved in periodontal diseases} |
G01N 33/56961 | . . . . . | { Plant cells or fungi} |
![]() | G01N 33/56966 | . . . . . | { Animal cells} |
![]() | G01N 33/56983 | . . . . . | { Viruses} |
G01N 33/56988 | . . . . . . | { AIDS or HTLV} |
G01N 33/56994 | . . . . . . | { Herpetoviridae, e.g. cytomegalovirus, Epstein-Barr virus} |
G01N 33/571 | . . . . . |
![]() | G01N 33/573 | . . . . | for enzymes or isoenzymes |
![]() | G01N 33/574 | . . . . | for cancer NOTE -
|
![]() | G01N 33/57407 | . . . . . | { Specifically defined cancers} |
G01N 33/57411 | . . . . . . | { of cervix} |
G01N 33/57415 | . . . . . . | { of breast} |
G01N 33/57419 | . . . . . . | { of colon} |
G01N 33/57423 | . . . . . . | { of lung} |
G01N 33/57426 | . . . . . . | { leukemia} |
G01N 33/5743 | . . . . . . | { of skin, melanoma} |
G01N 33/57434 | . . . . . . | { of prostate} |
G01N 33/57438 | . . . . . . | { of liver, pancreas or kidney} |
G01N 33/57442 | . . . . . . | { of the uterus and endometrial} |
G01N 33/57446 | . . . . . . | { of stomach or intestine} |
G01N 33/57449 | . . . . . . | { of ovaries} |
G01N 33/57469 | . . . . . | { involving tumor associated glycolinkage, i.e. TAG} |
G01N 33/57473 | . . . . . | { involving carcinoembryonic antigen, i.e. CEA} |
G01N 33/57476 | . . . . . | { involving oncofetal proteins} |
G01N 33/5748 | . . . . . | { involving oncogenic proteins} |
![]() | G01N 33/576 | . . . . | for hepatitis |
![]() | G01N 33/5761 | . . . . . | { Hepatitis B} |
G01N 33/5762 | . . . . . . | { Hepatitis B core antigen} |
G01N 33/5764 | . . . . . . | { Hepatitis B surface antigen} |
G01N 33/5765 | . . . . . | { Hepatitis delta antigen} |
G01N 33/5767 | . . . . . | { non-A, non-B hepatitis} |
G01N 33/5768 | . . . . . | { Hepatitis A} |
G01N 33/577 | . . . . | involving monoclonal antibodies { binding reaction mechanisms characterised by the use of monoclonal antibodies; monoclonal antibodies per se are classified with their corresponding antigens; G01N 33/53 to G01N 33/576 take precedence} |
G01N 33/579 | . . . | involving limulus lysate |
![]() | G01N 33/58 | . . . | involving labelled substances (G01N 33/53 takes precedence; for testing in vivo A61K 49/00) |
G01N 33/581 | . . . . | { with enzyme label (including co-enzymes, co-factors, enzyme inhibitors or substrates)} |
G01N 33/582 | . . . . | { with fluorescent label} |
G01N 33/583 | . . . . | { with non-fluorescent dye label} |
![]() | G01N 33/585 | . . . . | { with a particulate label, e.g. coloured latex} |
G01N 33/588 | . . . . | { with semiconductor nanocrystal label, e.g. quantum dots} |
G01N 33/60 | . . . . | involving radioactive labelled substances (tracers G21H 5/02) |
G01N 33/62 | . . . | involving urea |
G01N 33/64 | . . . | involving ketones |
G01N 33/66 | . . . | involving blood sugars, e.g. galactose |
![]() | G01N 33/68 | . . . |
![]() | G01N 33/6803 | . . . . | { General methods of protein analysis not limited to specific proteins or families of proteins} |
![]() | G01N 33/6806 | . . . . . | { Determination of free amino acids} |
G01N 33/6809 | . . . . . . | { involving fluorescent derivatizing reagents reacting non-specifically with all amino acids} |
![]() | G01N 33/6812 | . . . . . . | { Assays for specific amino acids} |
![]() | G01N 33/6818 | . . . . . | { Sequencing of polypeptides} |
G01N 33/6821 | . . . . . . | { involving C-terminal degradation} |
G01N 33/6824 | . . . . . . | { involving N-terminal degradation, e.g. Edman degradation} |
![]() | G01N 33/6827 | . . . . . | { Total protein determination, e.g. albumin in urine} |
![]() | G01N 33/683 | . . . . . . | { involving metal ions} |
G01N 33/6833 | . . . . . . . | { Copper, e.g. Folin-, Lowry-, biuret methods} |
G01N 33/6836 | . . . . . . . | { Silver staining} |
G01N 33/6839 | . . . . . . | { involving dyes, e.g. Coomassie blue, bromcresol green} |
G01N 33/6842 | . . . . . | { Proteomic analysis of subsets of protein mixtures with reduced complexity, e.g. membrane proteins, phosphoproteins, organelle proteins} |
G01N 33/6845 | . . . . . | { Methods of identifying protein-protein interactions in protein mixtures} |
![]() | G01N 33/6848 | . . . . . | { Methods of protein analysis involving mass spectrometry} |
![]() | G01N 33/6854 | . . . . | { Immunoglobulins} |
G01N 33/6872 | . . . . | { Intracellular protein regulatory factors and their receptors, e.g. including ion channels} |
G01N 33/6875 | . . . . | { Nucleoproteins} |
G01N 33/6878 | . . . . | { in eptitope analysis} |
G01N 33/6881 | . . . . | { from skin} |
G01N 33/6884 | . . . . | { from lung} |
G01N 33/6887 | . . . . | { from muscle, cartilage or connective tissue} |
G01N 33/689 | . . . . | { related to pregnancy or the gonads} |
![]() | G01N 33/6893 | . . . . | { related to diseases not provided for elsewhere} |
G01N 33/70 | . . . | involving creatine or creatinine |
![]() | G01N 33/72 | . . . | involving blood pigments, e.g. haemoglobin, bilirubin { or other porphyrins; involving occult blood} |
![]() | G01N 33/721 | . . . . | { Haemoglobin} |
G01N 33/723 | . . . . . | { Glycosylated haemoglobin} |
G01N 33/725 | . . . . . | { using peroxidative activity} |
G01N 33/726 | . . . . . | { Devices} |
G01N 33/728 | . . . . | { Bilirubin; including biliverdin} |
![]() | G01N 33/74 | . . . | involving hormones { or other non-cytokine intercellular protein regulatory factors such as growth factors, including receptors to hormones and growth factors} |
G01N 33/743 | . . . . | { Steroid hormones} |
G01N 33/746 | . . . . | { Erythropoetin} |
G01N 33/76 | . . . . | Human chorionic gonadotropin { including luteinising hormone, follicle stimulating hormone, thyroid stimulating hormone or their receptors} |
G01N 33/78 | . . . . | Thyroid gland hormones, { e.g. T3, T4, TBH, TBG or their receptors} |
G01N 33/80 | . . . |
G01N 33/82 | . . . | involving vitamins { or their receptors} |
G01N 33/84 | . . . | involving inorganic compounds or pH |
G01N 33/86 | . . . | involving blood coagulating time { or factors, or their receptors} |
G01N 33/88 | . . . | involving prostaglandins { or their receptors} |
G01N 33/90 | . . . | involving iron binding capacity of blood |
G01N 33/92 | . . . | involving lipids, e.g. cholesterol, { lipoproteins, or their receptors (steroid hormones G01N 33/743)} |
![]() | G01N 33/94 | . . . | involving narcotics { or drugs or pharmaceuticals, neurotransmitters or associated receptors} |
![]() | G01N 33/9406 | . . . . | { Neurotransmitters} |
G01N 33/9413 | . . . . . | { Dopamine} |
G01N 33/942 | . . . . . | { Serotonin, i.e. 5-hydroxy-tryptamine} |
G01N 33/9426 | . . . . . | { GABA, i.e. gamma-amino-butyrate} |
G01N 33/9433 | . . . . . | { (Nor)adrenaline} |
G01N 33/944 | . . . . . | { Acetylcholine} |
G01N 33/9446 | . . . . | { Antibacterials} |
G01N 33/9453 | . . . . | { Cardioregulators, e.g. antihypotensives, antiarrhythmics} |
G01N 33/946 | . . . . | { CNS-stimulants, e.g. cocaine, amphetamines} |
G01N 33/9466 | . . . . | { Antidepressants} |
G01N 33/9473 | . . . . | { Anticonvulsants, e.g. phenobarbitol, phenytoin} |
G01N 33/948 | . . . . |
G01N 33/9486 | . . . . | { Analgesics, e.g. opiates, aspirine} |
G01N 33/9493 | . . . . | { Immunosupressants} |
G01N 33/96 | . . . | involving blood or serum control standard |
G01N 33/98 | . . . | involving alcohol, e.g. ethanol in breath |
![]() | G01N 35/00 | Automatic analysis not limited to methods or materials provided for in any single one of groups G01N 1/00 to G01N 33/00; Handling materials therefor |
G01N 35/00009 | . | { provided with a sample supporting tape, e.g. with absorbent zones} |
![]() | G01N 35/00029 | . |
G01N 35/00069 | . . | { whereby the sample substrate is of the bio-disk type, i.e. having the format of an optical disk} |
![]() | G01N 35/00584 | . | { Control arrangements for automatic analysers} |
![]() | G01N 35/00594 | . . | { Quality control, including calibration or testing of components of the analyser} |
G01N 35/00603 | . . . | { Reinspection of samples} |
![]() | G01N 35/00613 | . . . | { Quality control} |
G01N 35/00693 | . . . | { Calibration} |
G01N 35/00712 | . . . | { Automatic status testing, e.g. at start-up or periodic} |
![]() | G01N 35/00722 | . . | { Communications; Identification} |
G01N 35/00732 | . . . | { Identification of carriers, materials or components in automatic analysers} |
G01N 35/00871 | . . . | { Communications between instruments or with remote terminals} |
![]() | G01N 35/0092 | . . | { Scheduling} |
G01N 35/0098 | . | { involving analyte bound to insoluble magnetic carrier, e.g. using magnetic separation (magnetic particles used in immunoassays G01N 33/54326; magnetic separation in general B03C)} |
G01N 35/0099 | . | [comprising robots or similar manipulators (robots per se B25J)] |
![]() | G01N 35/02 | . | using a plurality of sample containers moved by a conveyer system past one or more treatment or analysis stations { (G01N 35/0098 and G01N 35/0099 take precedence)} |
G01N 35/021 | . . | { having a flexible chain, e.g. "cartridge belt", conveyer for reaction cells or cuvettes} |
G01N 35/025 | . . | { having a carousel or turntable for reaction cells or cuvettes} |
G01N 35/026 | . . | { having blocks or racks of reaction cells or cuvettes} |
G01N 35/028 | . . | { having reaction cells in the form of micro-titration plates} |
G01N 35/04 | . . |
![]() | G01N 35/08 | . | using a stream of discrete samples flowing along a tube system, e.g. flow injection analysis |
![]() | G01N 35/10 | . | Devices for transferring samples { or any liquids} to, in, or from, the analysis apparatus, e.g. suction devices, injection devices { (G01N 35/0099 takes precedence)} |
G01N 35/1002 | . . | { Reagent dispensers} |
G01N 35/1004 | . . | { Cleaning sample transfer devices (cleaning laboratory glassware B01L11/00D)} |
![]() | G01N 35/1009 | . . | { Characterised by arrangements for controlling the aspiration or dispense of liquids} |
G01N 35/1011 | . . . | { Control of the position or alignment of the transfer device} |
G01N 35/1016 | . . . | { Control of the volume dispensed or introduced} |
![]() | G01N 35/1065 | . . | { Multiple transfer devices} |
G01N 35/1067 | . . . | { for transfer to or from containers having different spacing} |
G01N 35/1072 | . . . | { with provision for selective pipetting of individual channels} |
G01N 35/1074 | . . . | { arranged in a two-dimensional array} |
G01N 35/1079 | . . | { with means for piercing stoppers or septums} |
![]() | G01N 35/1081 | . . | { characterised by the means for relatively moving the transfer device and the containers in an horizontal plane (G01N 35/1011 takes precedence)} |
G01N 35/1083 | . . . | { with one horizontal degree of freedom} |
G01N 35/109 | . . . | { with two horizontal degrees of freedom} |
![]() | G01N 35/1095 | . . | { for supplying the samples to flow-through analysers (for a specific analyser see relevant groups, e.g. under G01N 15/00, G01N 21/00, G01N 27/00, G01N 30/00, H01J 49/00)} |
![]() | G01N 37/00 | Details not covered by any other group of this subclass |
![]() | G01N 2001/00 | Sampling; Preparing specimens for investigation |
![]() | G01N 2001/002 | . | Devices for supplying or distributing samples to an analysing apparatus |
G01N 2001/005 | . . | Packages for mailing or similar transprot of samples |
G01N 2001/007 | . . | Devices specially adapted for forensic samples, e.g. tamper-proofing, sample tracking |
![]() | G01N 2001/02 | . | Devices for withdrawing samples (for medical or veterinary purposes A61; { sampling of foundation soil E02D 1/04} ; obtaining samples of soil or well fluids E21B 49/00; { collecting or conveying radioactive samples G01T 7/00, e.g. G01T 7/02, G01T 7/08} ) |
G01N 2001/021 | . . | Correlating sampling sites with geographical information, e.g. GPS |
![]() | G01N 2001/022 | . . | sampling for security purposes, e.g. contraband, warfare agents |
G01N 2001/024 | . . . | passengers or luggage |
G01N 2001/025 | . . . | postal items |
G01N 2001/027 | . . . | field kits / quick test kits |
G01N 2001/028 | . . | Sampling from a surface, swabbing, vaporising |
![]() | G01N 2001/04 | . . | in the solid state, e.g. by cutting |
G01N 2001/045 | . . . | Laser ablation; Microwave vaporisation |
![]() | G01N 2001/06 | . . . | providing a thin slice, e.g. microtome |
![]() | G01N 2001/061 | . . . . | Blade details |
![]() | G01N 2001/065 | . . . . | Drive details |
G01N 2001/068 | . . . . | Illumination means |
![]() | G01N 2001/08 | . . . | involving an extracting tool, e.g. core bit |
![]() | G01N 2001/10 | . . | in the liquid or fluent state { burettes, pipettes B01L 3/02; Sampling of ground water E02D 1/06; metering by volume of fluids or fluent solid material G01F 11/00, G01F 13/00} |
![]() | G01N 2001/1006 | . . . | Dispersed solids |
![]() | G01N 2001/1031 | . . . | Sampling from special places |
G01N 2001/1037 | . . . . | from an enclosure (hazardous waste, radioactive) |
G01N 2001/1043 | . . . . | from sewers |
G01N 2001/105 | . . . . | from high-pressure reactors or lines |
G01N 2001/1056 | . . . | Disposable (single-use) samplers |
![]() | G01N 2001/1062 | . . . | Sampling under constant temperature, pressure, or the like |
G01N 2001/1068 | . . . . | Cooling sample below melting point |
G01N 2001/1075 | . . . . | Trapping evaporated liquids by cooling |
G01N 2001/1081 | . . . . | Storing samples under refrigeration |
![]() | G01N 2001/1087 | . . . | Categories of sampling |
![]() | G01N 2001/14 | . . . | Suction devices, e.g. pumps; Ejector devices |
![]() | G01N 2001/1418 | . . . . | Depression, aspiration |
![]() | G01N 2001/1445 | . . . . | Overpressure, pressurisation at sampling point |
![]() | G01N 2001/1472 | . . . . | Devices not actuated by pressure difference |
![]() | G01N 2001/18 | . . . | with provision for splitting samples into portions (G01N 1/12, G01N 1/14 take precedence; fraction-collection apparatus for chromatography B01D 15/08) |
![]() | G01N 2001/20 | . . . |
![]() | G01N 2001/2007 | . . . . | Flow conveyers |
G01N 2001/2014 | . . . . . | Pneumatic conveyers |
G01N 2001/2021 | . . . . . | falling under gravity |
G01N 2001/2028 | . . . . . | Belts |
![]() | G01N 2001/2035 | . . . . | { by deviating part of a fluid stream, e.g. by drawing-off or tapping} |
![]() | G01N 2001/205 | . . . . . | using a valve |
G01N 2001/2064 | . . . . . | using a by-pass loop |
![]() | G01N 2001/2071 | . . . . . | Removable sample bottle |
G01N 2001/2092 | . . . . | Cross-cut sampling |
![]() | G01N 2001/22 | . . | in the gaseous state { (specially adapted for biological material G01N 33/497; measuring breath flow A61B 5/087)} |
![]() | G01N 2001/2202 | . . . | { involving separation of sample components during sampling} |
![]() | G01N 2001/2226 | . . . | { Sampling from a closed space, e.g. food package, head space} |
![]() | G01N 2001/2229 | . . . . | Headspace sampling, i.e. vapour over liquid |
G01N 2001/2235 | . . . . | over a melt, e.g. furnace |
G01N 2001/2238 | . . . . | the gas being compressed or pressurized |
G01N 2001/2241 | . . . . | purpose-built sampling enclosure for emissions |
G01N 2001/2244 | . . . | Exhaled gas, e.g. alcohol detecting |
![]() | G01N 2001/2247 | . . . | { Sampling from a flowing stream of gas} |
G01N 2001/225 | . . . . | isokinetic, same flow rate for sample and bulk gas |
![]() | G01N 2001/2252 | . . . . | { in a vehicle exhaust} |
![]() | G01N 2001/2258 | . . . . | { in a stack or chimney} |
G01N 2001/2264 | . . . . | with dilution |
G01N 2001/2267 | . . . . | separating gas from liquid, e.g. bubbles |
G01N 2001/227 | . . . . | separating gas from solid, e.g. filter |
![]() | G01N 2001/2273 | . . . | { Atmospheric sampling} |
G01N 2001/2282 | . . . | with cooling means |
![]() | G01N 2001/2285 | . . . | Details of probe structures |
G01N 2001/2288 | . . . . | Filter arrangements |
G01N 2001/2291 | . . . . | Movable probes, e.g. swivelling, swinging |
G01N 2001/2297 | . . . | Timing devices |
![]() | G01N 2001/24 | . . . |
![]() | G01N 2001/28 | . | Preparing specimens for investigation { including physical details of (bio-)chemical methods covered elsewhere, e.g. G01N 33/50, C12Q} (mounting specimens on microscopic slides G02B 21/34; means for supporting the objects or the materials to be analysed in electron microscopes H01J 37/20; { laboratory gas handling apparatus B01L 5/00} ) |
![]() | G01N 2001/2813 | . . | { Producing thin layers of samples on a substrate, e.g. smearing, spinning-on (G01N 1/30 takes precedence)} |
G01N 2001/282 | . . . | with mapping; Identification of areas; Spatial correlated pattern |
G01N 2001/2826 | . . . | Collecting by adsorption or absorption |
![]() | G01N 2001/2833 | . . . | Collecting samples on a sticky, tacky, adhesive surface |
G01N 2001/2846 | . . . | Cytocentrifuge method |
![]() | G01N 2001/286 | . . |
G01N 2001/2893 | . . | Preparing calibration standards |
![]() | G01N 2001/30 | . . | Staining; Impregnating { Fixation; Dehydration; Multistep processes for preparing samples of tissue, cell or nucleic acid material and the like for analysis} |
G01N 2001/302 | . . . | Stain compositions |
![]() | G01N 2001/305 | . . . | Fixative compositions |
![]() | G01N 2001/31 | . . . | Apparatus therefor |
![]() | G01N 2001/36 | . . | Embedding or analogous mounting of samples |
G01N 2001/362 | . . . | using continuous plastic film to mount sample |
G01N 2001/364 | . . . | using resins, epoxy |
G01N 2001/366 | . . . | Moulds; Demoulding |
G01N 2001/368 | . . . | Mounting multiple samples in one block, e.g. TMA (Tissue Micro-arrays) |
![]() | G01N 2001/38 | . . | Diluting, dispersing or mixing samples |
G01N 2001/381 | . . . | by membrane diffusion; Permeation tubes |
G01N 2001/382 | . . . | using pistons of different sections |
G01N 2001/383 | . . . | collecting and diluting in a flow of liquid |
G01N 2001/385 | . . . | diluting by adsorbing a fraction of the sample |
![]() | G01N 2001/386 | . . . | Other diluting or mixing processes |
![]() | G01N 2001/40 | . . | Concentrating samples |
![]() | G01N 2001/4005 | . . . | { by transferring a selected component through a membrane} |
G01N 2001/4011 | . . . . | being a ion-exchange membrane |
G01N 2001/4016 | . . . . | being a selective membrane, e.g. dialysis or osmosis |
![]() | G01N 2001/4022 | . . . | { by thermal techniques; Phase changes} |
G01N 2001/4027 | . . . . | evaporation leaving a concentrated sample |
G01N 2001/4033 | . . . . | sample concentrated on a cold spot, e.g. condensation or distillation |
G01N 2001/4038 | . . . | electric methods, e.g. electromigration, electrophoresis, ionisation |
![]() | G01N 2001/4055 | . . . | { by solubility techniques} |
G01N 2001/4061 | . . . . | Solvent extraction |
G01N 2001/4066 | . . . . | using difference of solubility between liquid and gas, e.g. bubbling, scrubbing or sparging |
G01N 2001/4072 | . . . . | membraneless transfer of a component between two parallel laminar flows of fluid |
![]() | G01N 2001/4077 | . . . | { by other techniques involving separation of suspended solids} |
![]() | G01N 2009/00 | Investigating density or specific gravity of materials; Analysing materials by determining density or specific gravity (weighing apparatus G01G) |
![]() | G01N 2009/002 | . | { using variation of the resonant frequency of an element vibrating in contact with the material submitted to analysis (G01N 9/34 takes precedence)} |
G01N 2009/004 | . . | comparing frequencies of two elements |
G01N 2009/006 | . . | vibrating tube, tuning fork |
G01N 2009/008 | . . | Schlatter vibrating vane type |
![]() | G01N 2009/02 | . | by measuring weight of a known volume |
![]() | G01N 2009/26 | . | by measuring pressure differences |
![]() | G01N 2011/00 | Investigating flow properties of materials, e.g. viscosity, plasticity; Analysing materials by determining flow properties |
![]() | G01N 2011/0006 | . | Calibrating, controlling or cleaning viscometers |
G01N 2011/0013 | . . | Temperature compensation |
G01N 2011/002 | . . | Controlling sample temperature; Thermal cycling during measurement |
![]() | G01N 2011/0026 | . | Investigating specific flow properties of non-Newtonian fluids |
G01N 2011/0033 | . . | Yield stress; Residual stress at zero shear rate |
G01N 2011/004 | . . | Stress relaxation time |
![]() | G01N 2011/0046 | . | In situ measurement during mixing process |
![]() | G01N 2011/006 | . | Determining flow properties indirectly by measuring other parameters of the system |
G01N 2011/0066 | . . | electrical properties |
G01N 2011/0073 | . . | acoustic properties |
G01N 2011/008 | . . | optical properties |
G01N 2011/0086 | . . | magnetic properties |
G01N 2011/0093 | . . | thermal properties |
![]() | G01N 2011/10 | . | by moving a body within the material |
![]() | G01N 2011/14 | . . | by using rotary bodies, e.g. vane (G01N 11/16 takes precedence) |
G01N 2013/003 | . | Diffusion; diffusivity between liquids |
G01N 2013/006 | . | Dissolution of tablets or the like |
![]() | G01N 2013/02 | . | Investigating surface tension of liquids |
G01N 2013/0208 | . . | by measuring contact angle |
G01N 2013/0216 | . . | by measuring skin friction or shear force |
G01N 2013/0225 | . . | of liquid metals or solder |
G01N 2013/0233 | . . | Langmuir troughs; thin-film balances |
![]() | G01N 2013/0241 | . . | bubble, pendant drop, sessile drop methods |
G01N 2013/025 | . . . | Measuring foam stability |
G01N 2013/0258 | . . . | Oscillating drop methods |
G01N 2013/0266 | . . . | Bubble methods |
G01N 2013/0275 | . . | involving surface-active agents |
G01N 2013/0283 | . . | methods of calculating surface tension |
G01N 2013/0291 | . . | Wilhelmy plate |
![]() | G01N 2015/00 | Investigating characteristics of particles; Investigating permeability, pore-volume, or surface-area of porous materials (identification of micro-organisms C12Q) |
G01N 2015/0003 | . | Determining electric mobility, velocity profile, average speed or velocity of a plurality of particles |
![]() | G01N 2015/0007 | . | Investigating dispersion of gas |
G01N 2015/0019 | . | Means for transferring or separating particles prior to analysis, e.g hoppers or particle conveyors |
![]() | G01N 2015/0023 | . | Investigating dispersion of liquids |
G01N 2015/0026 | . . | in gas, e.g. fog |
G01N 2015/003 | . . | in liquids, e.g. emulsion |
G01N 2015/0034 | . . | in solids |
G01N 2015/0038 | . | Investigating nano particles |
![]() | G01N 2015/0042 | . | Investigating dispersion of solids |
![]() | G01N 2015/0046 | . . | in gas, e.g. smoke |
![]() | G01N 2015/0053 | . . | in liquids, e.g. trouble |
G01N 2015/0061 | . . | in solids, e.g. petrography |
![]() | G01N 2015/0065 | . | biological, e.g. blood |
G01N 2015/0069 | . . | with lysing, e.g. of erythrocyts |
![]() | G01N 2015/0073 | . . | Red blood cells |
G01N 2015/008 | . . | White cells |
G01N 2015/0084 | . . | Platelets |
G01N 2015/0088 | . . | Biological contaminants; Fouling |
G01N 2015/0092 | . | Monitoring flocculation or agglomeration |
G01N 2015/0096 | . | Investigating consistence of powders, dustability, dustiness |
![]() | G01N 2015/02 | . | Investigating particle size or size distribution (G01N 15/04, G01N 15/10 take precedence; by measuring osmotic pressure G01N 7/10; by filtering B01D; by sifting B07B) |
![]() | G01N 2015/0205 | . . | { by optical means, e.g. by light scattering, diffraction, holography or imaging} |
![]() | G01N 2015/0211 | . . . | { Investigating a scatter or diffraction pattern} |
G01N 2015/0216 | . . . . | from fluctuations of diffraction pattern |
G01N 2015/0222 | . . . . | from dynamic light scattering, e.g. photon correlation spectroscopy |
G01N 2015/0233 | . . . | using holography |
G01N 2015/0238 | . . . | Single particle scatter |
G01N 2015/0244 | . . . | with cutting-out molecular scatter |
G01N 2015/025 | . . . | Methods for single or grouped particles |
![]() | G01N 2015/0255 | . . | { with mechanical, e.g. inertial, classification, and investigation of sorted collections (with centrifuges G01N 15/042)} |
G01N 2015/0277 | . . | Average size only |
G01N 2015/0283 | . . | using control of suspension concentration |
G01N 2015/0288 | . . | Sorting the particles |
G01N 2015/0294 | . . | Particle shape |
![]() | G01N 2015/03 | . | Electro-optical investigation of a plurality of particles, the analyser being characterised by the optical arrangement |
![]() | G01N 2015/04 | . | Investigating sedimentation of particle suspensions |
![]() | G01N 2015/06 | . | Investigating concentration of particle suspensions (G01N 15/04, G01N 15/10 take precedence; by weighing G01N 5/00) NOTE -
|
G01N 2015/0662 | . . | Comparing before/after passage through filter |
G01N 2015/0668 | . . | Comparing properties of sample and carrier fluid, e.g. oil in water |
G01N 2015/0675 | . . | Comparing suspension before/after dilution |
G01N 2015/0681 | . . | Purposely modifying particles, e.g. humidifying for growing |
G01N 2015/0687 | . . | in solutions, e.g. non volatile residue |
G01N 2015/0693 | . . | by optical means, e.g. by integrated nephelometry |
![]() | G01N 2015/08 | . | Investigating permeability, pore-volume, or surface area of porous materials |
G01N 2015/0813 | . . | Measuring intrusion, e.g. of mercury |
G01N 2015/0833 | . . | Pore surface area |
G01N 2015/084 | . . | Testing filters |
G01N 2015/0846 | . . | by use of radiation, e.g. transmitted or reflected light |
G01N 2015/0853 | . . | by electrical capacitance measurement |
G01N 2015/086 | . . | of films, membranes or pellicules |
![]() | G01N 2015/0866 | . . | Sorption |
![]() | G01N 2015/10 | . | Investigating individual particles |
G01N 2015/1006 | . . | for cytology |
![]() | G01N 2015/1012 | . . | { Calibrating particle analysers; References therefor} |
G01N 2015/1018 | . . . | Constitution of reference particles |
G01N 2015/1025 | . . . | Particle flow simulating, e.g. liquid crystal cell |
G01N 2015/1037 | . . | Associating coulter-counter and optical flow cytometer (OFC) |
G01N 2015/1043 | . . | Measuring mass of individual particles |
G01N 2015/105 | . . | Other than optical measurement of deformation of individual particles (optical measurement G01N 2015/1495) |
G01N 2015/1062 | . . | counting the particles by other than electro-optical means (by electro-optical means G01N 2015/1486) |
G01N 2015/1068 | . . | Recognizing failure of the analyser, e.g. bubbles; Quality control for particle analysers |
G01N 2015/1075 | . . | Determining speed or velocity of a particle |
G01N 2015/1081 | . . | Sorting the particles |
G01N 2015/1087 | . . | Particle size |
G01N 2015/1093 | . . | Particle shape |
![]() | G01N 2015/12 | . . | Coulter-counters |
![]() | G01N 2015/1209 | . . . | { Details} |
![]() | G01N 2015/1254 | . . . | Electrodes |
G01N 2015/1272 | . . . | Cleaning |
G01N 2015/1281 | . . . | Detecting blocking debris |
G01N 2015/129 | . . . | measuring the ratio of AC/DC impedances |
![]() | G01N 2015/14 | . . | Electro-optical investigation, e.g. flow cytometers |
G01N 2015/1402 | . . . | Data analysis by thresholding or gating operations performed on the acquired signals or stored data |
![]() | G01N 2015/1404 | . . . | { Fluid conditioning in flow cytometers, e.g. flow cells; Supply; Control of flow} |
G01N 2015/1406 | . . . . | Control of droplet point |
![]() | G01N 2015/1409 | . . . . | Control of supply of sheaths fluid, e.g. sample injection control |
G01N 2015/1413 | . . . . | Hydrodynamic focussing |
G01N 2015/1415 | . . . . | Control of particle position |
G01N 2015/1418 | . . . . | Eliminating clogging of debris |
G01N 2015/142 | . . . . | Acoustic or ultrasonic focussing |
G01N 2015/1422 | . . . . | Electrical focussing |
![]() | G01N 2015/1434 | . . . | { using an analyser being characterised by its optical arrangement} |
G01N 2015/1438 | . . . . | Using two lasers in succession |
![]() | G01N 2015/144 | . . . . | Imaging characterised by its optical setup |
G01N 2015/1443 | . . . . . | Auxiliary imaging |
![]() | G01N 2015/1447 | . . . . | Spatial selection |
G01N 2015/1452 | . . . . | Adjustment of focus; Alignment |
G01N 2015/1454 | . . . . | using phase shift or interference, e.g. for improving contrast |
![]() | G01N 2015/1456 | . . . | { without spatial resolution of the texture or inner structure of the particle, e.g. processing of pulse signals} |
G01N 2015/1461 | . . . . | Coincidence detecting; Circuits therefor |
![]() | G01N 2015/1463 | . . . . | { using image analysis for extracting features of the particle} NOTE -
|
![]() | G01N 2015/1468 | . . . | { with spatial resolution of the texture or inner structure of the particle} { Informative Note References listed below indicate CPC places which could also be interest when carrying out a search in respect of the subject matter covered by the preceding group: -counting objects disposed at random with size distrinction G06M 11/04 -extraction of features from image for pattern recognition G06K 9/46 -specific image analysis method for the recognition of microscopic objects G06K 9/00127 -image enhancement in general G06T 5/00 -image analysis in general G06T 7/00} NOTE -
|
![]() | G01N 2015/1477 | . . . | Multiparameters |
G01N 2015/1481 | . . . | Optical analysis of particle in droplet |
G01N 2015/1486 | . . . | Counting the particles |
G01N 2015/1488 | . . . | Methods for deciding |
G01N 2015/149 | . . . | Sorting the particles |
![]() | G01N 2015/1493 | . . . | Particle size |
G01N 2015/1497 | . . . | Particle shape |
![]() | G01N 2021/00 | Investigating or analysing materials by the use of optical means, i.e. using infra-red, visible, or ultra-violet light (G01N 3/00 to G01N 19/00 take precedence; measuring stress in general G01L 1/00; optical elements of measuring instruments G02B) NOTE -
|
![]() | G01N 2021/01 | . | Arrangements or apparatus for facilitating the optical investigation |
![]() | G01N 2021/0106 | . . | General arrangement of respective parts |
G01N 2021/0112 | . . . | Apparatus in one mechanical, optical or electronic block |
![]() | G01N 2021/0118 | . . . | Apparatus with remote processing |
![]() | G01N 2021/0125 | . . . . | with stored program or instructions |
G01N 2021/0137 | . . . . | with PC or the like |
G01N 2021/0143 | . . . . | with internal and external computer |
![]() | G01N 2021/015 | . . . | Apparatus with interchangeable optical heads or interchangeable block of optics and detector |
![]() | G01N 2021/0162 | . . | using microprocessors for control of a sequence of operations, e.g. test, powering, switching, processing |
G01N 2021/0181 | . . | Memory or computer-assisted visual determination |
G01N 2021/0187 | . . | Mechanical sequence of operations |
G01N 2021/0193 | . . | the sample being taken from a stream or flow to the measurement cell |
![]() | G01N 2021/03 | . . | Cuvette constructions |
![]() | G01N 2021/0303 | . . . | { Optical path conditioning in cuvettes, e.g. windows; adapted optical elements or systems; path modifying or adjustment (G01N 21/031 to G01N 21/15 take precedence)} |
![]() | G01N 2021/031 | . . . | { Multipass arrangements} |
G01N 2021/0321 | . . . | One time use cells, e.g. integrally moulded |
![]() | G01N 2021/0325 | . . . | Cells for testing reactions, e.g. containing reagents |
G01N 2021/0328 | . . . . | Arrangement of two or more cells having different functions for the measurement of reactions |
![]() | G01N 2021/0332 | . . . |
G01N 2021/0339 | . . . | Holders for solids, powders |
G01N 2021/0342 | . . . | Solid sample being immersed, e.g. equiindex fluid |
![]() | G01N 2021/0346 | . . . | Capillary cells; Microcells |
G01N 2021/0357 | . . . | Sets of cuvettes |
G01N 2021/036 | . . . | transformable, modifiable |
G01N 2021/0364 | . . . | flexible, compressible |
![]() | G01N 2021/0367 | . . . | Supports of cells, e.g. pivotable |
![]() | G01N 2021/0378 | . . . | Shapes |
G01N 2021/0385 | . . . | Diffusing membrane; Semipermeable membrane |
![]() | G01N 2021/0389 | . . . | Windows |
![]() | G01N 2021/05 | . . . | Flow-through cuvettes (G01N 21/09 takes precedence; handling fluid samples G01N 1/10) |
![]() | G01N 2021/11 | . . | Filling or emptying of cuvettes |
![]() | G01N 2021/13 | . . | Moving of cuvettes or solid samples to or from the investigating station { handling materials for automatic analysis G01N 35/00} |
G01N 2021/135 | . . . | Sample holder displaceable (in automatised apparatus G01N 35/02) |
![]() | G01N 2021/15 | . . | Preventing contamination of the components of the optical system or obstruction of the light path |
![]() | G01N 2021/17 | . | Systems in which incident light is modified in accordance with the properties of the material investigated (where the material investigated is optically excited causing a change in wavelength of the incident light G01N 21/63) |
![]() | G01N 2021/1702 | . . | { with opto-acoustic detection, e.g. for gases or analysing solids} |
G01N 2021/1704 | . . . | in gases |
G01N 2021/1706 | . . . | in solids |
G01N 2021/1708 | . . . | with piezotransducers (probes for investigating or analysing materials by the use of ultrasonic, sonic or infrasonic waves G01N 29/24) |
![]() | G01N 2021/171 | . . | { with calorimetric detection, e.g. with thermal lens detection} |
G01N 2021/1712 | . . . | Thermal lens, mirage effect |
G01N 2021/1714 | . . . | Photothermal radiometry with measurement of emission |
![]() | G01N 2021/1717 | . . | { with a modulation of one or more physical properties of the sample during the optical investigation, e.g. electro-reflectance} |
G01N 2021/1719 | . . . | Carrier modulation in semiconductors |
G01N 2021/1721 | . . . | Electromodulation |
G01N 2021/1723 | . . . | Fluid modulation |
G01N 2021/1725 | . . . | Modulation of properties by light, e.g. photoreflectance |
G01N 2021/1727 | . . . | Magnetomodulation |
G01N 2021/1729 | . . . | Piezomodulation |
G01N 2021/1731 | . . . | Temperature modulation |
![]() | G01N 2021/1734 | . . | Sequential different kinds of measurements; Combining two or more methods |
![]() | G01N 2021/1738 | . . | Optionally different kinds of measurements; Method being valid for different kinds of measurement |
G01N 2021/174 | . . . | either absorption-reflection or emission-fluorescence |
G01N 2021/1742 | . . . | either absorption or reflection |
G01N 2021/1744 | . . . | either absorption or scatter |
G01N 2021/1746 | . . | Method using tracers |
![]() | G01N 2021/1748 | . . | Comparative step being essential in the method |
![]() | G01N 2021/1757 | . . | Time modulation of light being essential to the method of light modification, e.g. using single detector (circuits for photometry with modulation, using one detector S01J1/44M) |
![]() | G01N 2021/1761 | . . | A physical transformation being implied in the method, e.g. a phase change |
![]() | G01N 2021/1765 | . . | Method using an image detector and processing of image signal |
![]() | G01N 2021/178 | . . | Methods for obtaining spatial resolution of the property being measured |
![]() | G01N 2021/1789 | . . | Time resolved |
![]() | G01N 2021/1793 | . . | Remote sensing |
![]() | G01N 2021/21 | . . | Polarisation-affecting properties (G01N 21/19 takes precedence) |
![]() | G01N 2021/211 | . . . |
G01N 2021/212 | . . . . | Arrangement with total internal reflection |
G01N 2021/213 | . . . . | Spectrometric ellipsometry |
G01N 2021/214 | . . . . | Variangle incidence arrangement |
G01N 2021/215 | . . . . | Brewster incidence arrangement |
G01N 2021/216 | . . . | using circular polarised light |
G01N 2021/217 | . . . | Measuring depolarisation or comparing polarised and depolarised parts of light |
G01N 2021/218 | . . . | Measuring properties of electrooptical or magnetooptical media |
![]() | G01N 2021/25 | . . | Colour; Spectral properties, i.e. comparison of effect of material on the light at two or more different wavelengths or wavelength bands |
G01N 2021/258 | . . . | Surface plasmon spectroscopy, e.g. micro- or nano- particles in suspension |
![]() | G01N 2021/29 | . . . | using visual detection (G01N 21/31 takes precedence) |
![]() | G01N 2021/31 | . . . | Investigating relative effect of material at wavelengths characteristic of specific elements or molecules, e.g. atomic absorption spectrometry { (G01N 21/72 takes precedence)} |
![]() | G01N 2021/3103 | . . . . | { Atomic absorption analysis} |
G01N 2021/3107 | . . . . . | Cold vapor, e.g. determination of Hg |
G01N 2021/3111 | . . . . . | using Zeeman split |
G01N 2021/3114 | . . . . . | Multi-element AAS arrangements |
G01N 2021/3118 | . . . . . | Commutating sources, e.g. line source/broad source, chopping for comparison of broad/narrow regimes |
G01N 2021/3122 | . . . . . | using a broad source with a monochromator |
G01N 2021/3125 | . . . . | Measuring the absorption by excited molecules |
![]() | G01N 2021/3129 | . . . . | Determining multicomponents by multiwavelength light |
G01N 2021/3133 | . . . . . | with selection of wavelengths before the sample |
G01N 2021/3137 | . . . . . | with selection of wavelengths after the sample |
![]() | G01N 2021/314 | . . . . | { with comparison of measurements at specific and non-specific wavelengths (dual wavelength spectrometry G01J 3/427)} |
G01N 2021/3144 | . . . . . | for oxymetry |
G01N 2021/3148 | . . . . . | using three or more wavelengths |
G01N 2021/3155 | . . . . . | Measuring in two spectral ranges, e.g. UV and visible |
![]() | G01N 2021/3159 | . . . . . | Special features of multiplexing circuits |
G01N 2021/3166 | . . . . . | using separate detectors and filters |
![]() | G01N 2021/317 | . . . . . | Special constructive features |
G01N 2021/3174 | . . . . . . | Filter wheel |
G01N 2021/3177 | . . . . . . | Use of spatially separated filters in simultaneous way |
G01N 2021/3181 | . . . . . | using LEDs |
![]() | G01N 2021/3185 | . . . . | typically monochromatic or band-limited |
G01N 2021/3196 | . . . . | Correlating located peaks in spectrum with reference data, e.g. fingerprint data |
![]() | G01N 2021/33 | . . . . | using ultra-violet light (G01N 21/39 takes precedence) |
![]() | G01N 2021/35 | . . . . | using infra-red light (G01N 21/39 takes precedence) |
![]() | G01N 2021/3504 | . . . . . | { for analysing gases, e.g. multigases analysis} |
G01N 2021/3509 | . . . . . . | Correlation method, e.g. one beam alternating in correlator/sample field |
G01N 2021/3513 | . . . . . . | Open path with an instrumental source |
![]() | G01N 2021/3518 | . . . . . . | { Devices using the gas filter correlation method including the radiometric type, i.e. without instrumental source; Devices using gas pressure modulation method} |
G01N 2021/3522 | . . . . . . . | balancing by two filters on two detectors |
G01N 2021/3527 | . . . . . . . | and using one filter cell as attenuator |
G01N 2021/3531 | . . . . . . | without instrumental source, i.e. radiometric |
G01N 2021/3536 | . . . . . . | using modulation of pressure or density |
G01N 2021/354 | . . . . . . | Hygrometry of gases |
![]() | G01N 2021/3545 | . . . . . . | Disposition for compensating effect of interfering gases |
![]() | G01N 2021/3563 | . . . . . | { for analysing solids; preparation of samples therefor (sampling or preparing specimen for investigation in general G01N 1/00)} |
G01N 2021/3568 | . . . . . . | applied to semiconductors, e.g. Silicon |
G01N 2021/3572 | . . . . . . | Preparation of samples, e.g. salt matrices |
G01N 2021/3595 | . . . . . | using FTIR |
![]() | G01N 2021/39 | . . . . | using tunable lasers |
G01N 2021/391 | . . . . . | Intracavity sample |
![]() | G01N 2021/392 | . . . . . | Measuring reradiation, e.g. fluorescence, backscatter |
G01N 2021/393 | . . . . . . | and using a spectral variation of the interaction of the laser beam and the sample |
G01N 2021/394 | . . . . . | DIAL method |
G01N 2021/395 | . . . . . | using a topographic target |
![]() | G01N 2021/396 | . . . . . | Type of laser source |
![]() | G01N 2021/41 | . . | Refractivity; Phase-affecting properties, e.g. optical path length (G01N 21/21 takes precedence) |
![]() | G01N 2021/4106 | . . . | Atmospheric distortion; Turbulence |
G01N 2021/4126 | . . . | Index of thin films |
![]() | G01N 2021/4133 | . . . | { Refractometers, e.g. differential} |
G01N 2021/414 | . . . . | Correcting temperature effect in refractometers |
G01N 2021/4146 | . . . . | Differential cell arrangements |
G01N 2021/4153 | . . . . | Measuring the deflection of light in refractometers |
G01N 2021/416 | . . . | Visualising flow by index measurement |
G01N 2021/4166 | . . . | Methods effecting a waveguide mode enhancement through the property being measured |
![]() | G01N 2021/4173 | . . . | Phase distribution |
G01N 2021/418 | . . . . | Frequency/phase diagrams |
G01N 2021/4186 | . . . . | Phase modulation imaging |
G01N 2021/4193 | . . . . | using a PSD |
![]() | G01N 2021/43 | . . . | by measuring critical angle |
![]() | G01N 2021/431 | . . . . | { Dip refractometers, e.g. using optical fibres} |
G01N 2021/434 | . . . . | Dipping block in contact with sample, e.g. prism |
G01N 2021/435 | . . . . | Sensing drops on the contact surface |
![]() | G01N 2021/436 | . . . . | Sensing resonant reflection |
![]() | G01N 2021/45 | . . . | using interferometric methods; using Schlieren methods |
![]() | G01N 2021/47 | . . | Scattering, i.e. diffuse reflection (G01N 21/25, G01N 21/41 take precedence) { G01N 21/55 takes precedence} |
G01N 2021/4702 | . . . | Global scatter; Total scatter, excluding reflections |
![]() | G01N 2021/4704 | . . . | Angular selective |
G01N 2021/4707 | . . . . | Forward scatter; Low angle scatter |
G01N 2021/4709 | . . . . | Backscatter |
![]() | G01N 2021/4711 | . . . . | Multiangle measurement |
G01N 2021/4714 | . . . . . | Continuous plural angles |
G01N 2021/4716 | . . . . . | Using a ring of sensors, or a combination of diaphragm and sensors; Annular sensor |
G01N 2021/4719 | . . . . . | using a optical fibre array |
G01N 2021/4721 | . . . . . | using a PSD |
G01N 2021/4723 | . . . . . | Scanning scatter angles |
G01N 2021/4726 | . . . . | Detecting scatter at 90° |
G01N 2021/4728 | . . . . | Optical definition of scattering volume |
G01N 2021/473 | . . . | Compensating for unwanted scatter, e.g. reliefs, marks |
G01N 2021/4733 | . . . | Discriminating different types of scatterers |
G01N 2021/4735 | . . . | Solid samples, e.g. paper, glass |
![]() | G01N 2021/4738 | . . . | { Diffuse reflection (precedence is given to G01N 21/55-G01N 21/57 if specular component is taken into consideration), e.g. also for testing fluids, fibrous materials} |
![]() | G01N 2021/474 | . . . . | { Details of optical heads therefor, e.g. using optical fibres} |
![]() | G01N 2021/4742 | . . . . . | comprising optical fibres |
G01N 2021/4745 | . . . . . . | Fused bundle, i.e. for backscatter |
G01N 2021/4747 | . . . . . . | Concentric bundles |
G01N 2021/475 | . . . . . . | Bifurcated bundle |
![]() | G01N 2021/4752 | . . . . . | Geometry |
![]() | G01N 2021/4764 | . . . . | Special kinds of physical applications |
G01N 2021/4766 | . . . . . | Sample containing fluorescent brighteners |
G01N 2021/4769 | . . . . . | Fluid samples, e.g. slurries, granulates; Compressible powdery of fibrous samples |
G01N 2021/4771 | . . . . . | Matte surfaces with reflecting particles |
G01N 2021/4773 | . . . . . | Partly or totally translucent samples |
![]() | G01N 2021/4776 | . . . . | Miscellaneous in diffuse reflection devices |
![]() | G01N 2021/4788 | . . . |
G01N 2021/4792 | . . . | Polarisation of scatter light |
![]() | G01N 2021/4795 | . . . |
![]() | G01N 2021/49 | . . . | within a body or fluid |
G01N 2021/495 | . . . . | the fluid being adsorbed, e.g. in porous medium |
![]() | G01N 2021/51 | . . . . | inside a container, e.g. in an ampoule (G01N 21/53 takes precedence; checking containers for cleanliness B08B 9/46) |
G01N 2021/513 | . . . . . | Cuvettes for scattering measurements |
G01N 2021/516 | . . . . . | Multiple excitation of scattering medium, e.g. by retro-reflected or multiply reflected excitation rays |
![]() | G01N 2021/53 | . . . . | within a flowing fluid, e.g. smoke (alarm devices actuated by smoke G08B 17/10) |
![]() | G01N 2021/55 | . . | Specular reflectivity |
G01N 2021/551 | . . . | Retroreflectance |
G01N 2021/555 | . . . | Measuring total reflection power, i.e. scattering and specular |
G01N 2021/556 | . . . | Measuring separately scattering and specular |
G01N 2021/557 | . . . | Detecting specular reflective parts on sample |
G01N 2021/558 | . . . | Measuring reflectivity and transmission |
G01N 2021/559 | . . . | Determining variation of specular reflection within diffusively reflecting sample |
![]() | G01N 2021/57 | . . . | Measuring gloss |
![]() | G01N 2021/59 | . . | Transmissivity (G01N 21/25 takes precedence) |
G01N 2021/5903 | . . . | using surface plasmon resonance [SPR], e.g. extraordinary optical transmission [EOT] |
![]() | G01N 2021/5907 | . . . | { Densitometers} |
![]() | G01N 2021/5915 | . . . . | Processing scan data in densitometry |
G01N 2021/5919 | . . . . . | Determining total density of a zone |
G01N 2021/5923 | . . . . . | Determining zones of density; quantitating spots |
G01N 2021/5926 | . . . . . | Isodensitometers |
G01N 2021/593 | . . . . . | Correcting from the background density |
G01N 2021/5934 | . . . . . | Averaging on a zone |
G01N 2021/5938 | . . . . . | Features of monitor, display |
G01N 2021/5942 | . . . . . | for dot area ratio in printing applications |
G01N 2021/5946 | . . . . . | for binary signal |
G01N 2021/5949 | . . . . . | Correcting nonlinearity of signal, e.g. in measurement of photomedium |
G01N 2021/5953 | . . . . . | for detecting a spatial spectrum |
![]() | G01N 2021/5957 | . . . . | using an image detector type detector, e.g. CCD |
G01N 2021/5961 | . . . . . | using arrays of sources and detectors |
G01N 2021/5965 | . . . . . | using selected detectors in an array |
![]() | G01N 2021/5969 | . . . . | Scanning of a tube, a cuvette, a volume of sample |
G01N 2021/5976 | . . . . | Image projected and scanning projected image |
![]() | G01N 2021/598 | . . . . | Features of mounting, adjusting |